Background And Purpose: Dynamic contrast-enhanced MR imaging parameters can be biased by poor measurement of the vascular input function. We have compared the diagnostic accuracy of dynamic contrast-enhanced MR imaging by using a phase-derived vascular input function and "bookend" T1 measurements with DSC MR imaging for preoperative grading of astrocytomas.
Materials And Methods: This prospective study included 48 patients with a new pathologic diagnosis of an astrocytoma. Preoperative MR imaging was performed at 3T, which included 2 injections of 5-mL gadobutrol for dynamic contrast-enhanced and DSC MR imaging. During dynamic contrast-enhanced MR imaging, both magnitude and phase images were acquired to estimate plasma volume obtained from phase-derived vascular input function (Vp_Φ) and volume transfer constant obtained from phase-derived vascular input function (K(trans)_Φ) as well as plasma volume obtained from magnitude-derived vascular input function (Vp_SI) and volume transfer constant obtained from magnitude-derived vascular input function (K(trans)_SI). From DSC MR imaging, corrected relative CBV was computed. Four ROIs were placed over the solid part of the tumor, and the highest value among the ROIs was recorded. A Mann-Whitney U test was used to test for difference between grades. Diagnostic accuracy was assessed by using receiver operating characteristic analysis.
Results: Vp_ Φ and K(trans)_Φ values were lower for grade II compared with grade III astrocytomas (P < .05). Vp_SI and K(trans)_SI were not significantly different between grade II and grade III astrocytomas (P = .08-0.15). Relative CBV and dynamic contrast-enhanced MR imaging parameters except for K(trans)_SI were lower for grade III compared with grade IV (P ≤ .05). In differentiating low- and high-grade astrocytomas, we found no statistically significant difference in diagnostic accuracy between relative CBV and dynamic contrast-enhanced MR imaging parameters.
Conclusions: In the preoperative grading of astrocytomas, the diagnostic accuracy of dynamic contrast-enhanced MR imaging parameters is similar to that of relative CBV.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7964869 | PMC |
http://dx.doi.org/10.3174/ajnr.A4398 | DOI Listing |
Curr Med Imaging
January 2025
Department of Pathology, Affiliated Jinhua Hospital Zhejiang University School of Medicine, Jinhua, Zhejiang, 32100, P. R. China.
Introduction: Mucinous Cystadenocarcinoma (MCA) of the breast remains a relatively rare condition, and to date, there is no systematic summary of its imaging manifestations. Therefore, this report presents a detailed account of the diagnosis and treatment of mucinous cystadenocarcinoma in a 40-year-old woman, with a particular focus on imaging findings. Additionally, we conducted a comprehensive literature review on this disease and summarized its key imaging features.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Biomedical Engineering, Cardiology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands; Medical Imaging, Department of Imaging Physics, Faculty of Applied Sciences, Delft University of Technology, Delft, the Netherlands. Electronic address:
Objective: Assessing myocardial perfusion in acute myocardial infarction is important for guiding clinicians in choosing appropriate treatment strategies. Echocardiography can be used due to its direct feedback and bedside nature, but it currently faces image quality issues and an inability to differentiate coronary macro- from micro-circulation. We previously developed an imaging scheme using high frame-rate contrast-enhanced ultrasound (HFR CEUS) with higher order singular value decomposition (HOSVD) that provides dynamic perfusion and vascular flow visualization.
View Article and Find Full Text PDFSleep Med
January 2025
Department of Radiology, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University Nanchang, 330006, China; Intelligent Medical Imaging of Jiangxi Key Laboratory, 330006, Nanchang, China; School of Biomedical Engineering, National Graduate College for Engineers, Tsinghua University, 100084, Beijing, China. Electronic address:
Background: Sleep is associated with glymphatic circulation activity; however, there is no direct imaging modality to validate glymphatic circulation disorders in patients with insomnia. Therefore, this study aimed to explore the relationship between insomnia disorder (ID) and the glymphatic system. Dynamic synthetic magnetic resonance imaging (syMRI) was performed.
View Article and Find Full Text PDFUrol Oncol
January 2025
Research Department, Urovallarta Medical Center, Puerto Vallarta, Mexico.
Background: Multiparametric MRI (Mp-MRI) is a key tool to screen for Prostate Cancer (Pca) and Clinically Significant Prostate Cancer (CsPca). It primarily includes T2-Weighted imaging (T2w), diffusion-weighted imaging (DWI), and Dynamic Contrast-Enhanced imaging (DCE). Despite its improvements in CsPca screening, concerns about the cost-effectiveness of DCE persist due to its associated side effects, increased cost, longer acquisition time, and limitations in patients with poor kidney function.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China. Electronic address:
Objective: To evaluate the added value of dynamic contrast-enhanced ultrasound (DCE-US) analysis in pre-operative differential diagnosis of small (≤20 mm) solid pancreatic lesions (SPLs).
Methods: In this retrospective study, patients with biopsy or surgerical resection and histopathologically confirmed small (≤20 mm) SPLs were included. One wk before biopsy/surgery, pre-operative B-mode ultrasound and contrast-enhanced ultrasound were performed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!