Objective: To measure distances between pulmonary veins (PV) and mitral annulus (MA) using angiographic computed tomography (CT) and to compare them with the left atrial appendage-MA (LAA-MA) line.
Materials And Methods: Data from 46 catheter ablation procedures for atrial fibrillation involving 36 males, mean age 53 years, range 27-78 years, were analyzed. Three types of mitral isthmus lines were measured using angiographic CT images integrated in the CARTO 3 system (Biosense Webster): the distance between the right superior PV and MA (RSPV-MA), the right inferior PV and MA (RIPV-MA), and the left inferior PV and MA (LIPV-MA). They were compared with the length of the LAA-MA line.
Results: The mean value of LIPV-MA was 29 ± 11.2 mm, RIPV-MA 39 ± 8.2 mm, and RSPV-MA 48 ± 8.2 mm. The circumflex artery (CxA) and the coronary sinus (CS) were closest to the LIPV-MA line. Compared with the three isthmus lines, the LAA-MA was the shortest (24.7 ± 15.6 mm), and the difference was statistically significant (p < 0.05).
Conclusion: The angiographic CT provided detailed information regarding the anatomy of the left atrium and distances between atrial structures. The LAA-MA was shorter than the other three lines with the CxA and CS situated at a distance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5588268 | PMC |
http://dx.doi.org/10.1159/000431371 | DOI Listing |
Echocardiography
January 2025
Echocardiography Department, National Institute of Cardiology Ignacio Chávez, México City, México.
We present a case of a 72-year-old female patient with dyspnea and lipothymia. Echocardiography demonstrates an intracavitary cystic mass that fills almost all left atria causing supravalvular obstruction. The magnetic resonance image revealed a 53 × 47 × 48 mm heterogeneous mass with regular edges, tissue characterization suggested myxoma.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, University Heart Center Lübeck, Lübeck, Germany.
Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.
Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.
Cureus
November 2024
Internal Medicine, Shri Ram Murti Smarak Institute of Medical Sciences, Bareilly, IND.
Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.
View Article and Find Full Text PDFPol J Vet Sci
September 2024
Department of Biostatistics, Faculty of Veterinary Medicine, Hatay Mustafa Kemal University, 31060, Hatay, Turkey.
The aim of this study was to evaluate the association between spontaneous echocardiographic contrast (SEC) and left atrial (LA) parameters such as size, volume, and function in cats with hypertrophic cardiomyopathy (HCM). Cats were assigned into following groups: clinically healthy cats (n=8), HCM without SEC (n=12), and HCM with SEC (n=8). Left atrial shortening fraction (LAFS%) and left atrial fractional area change (LAFAC) had statistical significance between groups.
View Article and Find Full Text PDFPol J Vet Sci
December 2024
Department of Epizootiology and the Clinic of Infectious Diseases, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Głęboka 30, 20-612 Lublin, Poland.
The effects of T4 are mainly manifested by positive ino- and chronotropism. The syndrome accompanying hypothyroidism in rabbits (impaired myocardial contractility and reduced ejection capacity) is caused by a deficiency of thyroid hormones - especially T4. The study group consisted of a total of 41 animals: 15 males and 26 females, ranging in age from 2 months to 8 years, with echocardiogram showing reduced fractional shortening (<30%), with normal results of heamatological and biochemical tests.