The CNAP system (CNSystems Medizintechnik AG, Graz, Austria) provides noninvasive continuous arterial pressure measurements by using the volume clamp method. Recently, an algorithm for the determination of cardiac output by pulse contour analysis of the arterial waveform recorded with the CNAP system became available. We evaluated the agreement of the continuous noninvasive cardiac output (CNCO) measurements by CNAP in comparison with cardiac output measurements invasively obtained using transpulmonary thermodilution (TDCO). In this proof-of-concept analysis we studied 38 intensive care unit patients from a previously set up database containing CNAP-derived arterial pressure data and TDCO values obtained with the PiCCO system (Pulsion Medical Systems SE, Feldkirchen, Germany). We applied the new CNCO algorithm retrospectively to the arterial pressure waveforms recorded with CNAP and compared CNCO with the corresponding TDCO values (criterion standard). Analyses were performed separately for (1) CNCO calibrated to the first TDCO (CNCO-cal) and (2) CNCO autocalibrated to biometric patient data (CNCO-auto). We did not perform an analysis of trending capabilities because the patients were hemodynamically stable. The median age and APACHE II score of the 22 male and 16 female patients was 63 years and 18 points, respectively. 18 % were mechanically ventilated and in 29 % vasopressors were administered. Mean ± standard deviation for CNCO-cal, CNCO-auto, and TDCO was 8.1 ± 2.7, 6.4 ± 1.9, and 7.8 ± 2.4 L/min, respectively. For CNCO-cal versus TDCO, Bland-Altman analysis demonstrated a mean difference of +0.2 L/min (standard deviation 1.0 L/min; 95 % limits of agreement -1.7 to +2.2 L/min, percentage error 25 %). For CNCO-auto versus TDCO, the mean difference was -1.4 L/min (standard deviation 1.8 L/min; 95 % limits of agreement -4.9 to +2.1 L/min, percentage error 45 %). This pilot analysis shows that CNCO determination is feasible in critically ill patients. A percentage error of 25 % indicates acceptable agreement between CNCO-cal and TDCO. The mean difference, the standard deviation, and the percentage error between CNCO-auto and TDCO were higher than between CNCO-cal and TDCO. A hyperdynamic cardiocirculatory state in a substantial number of patients and the hemodynamic stability making trending analysis impossible are main limitations of our study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-015-9744-1DOI Listing

Publication Analysis

Top Keywords

cardiac output
20
percentage error
16
cnap system
12
arterial pressure
12
standard deviation
12
tdco
9
continuous noninvasive
8
noninvasive cardiac
8
volume clamp
8
pulse contour
8

Similar Publications

Context: The impacts of elevated ketone body levels on cardiac function and hemodynamics in patients with heart failure (HF) remain unclear.

Objective: The effects of ketone intervention on these parameters in patients with HF were evaluated quantitatively in this meta-analysis.

Data Sources: We searched the PubMed, Cochrane Library, and Embase databases for relevant studies published from inception to April 13, 2024.

View Article and Find Full Text PDF

Background: Idiopathic right bundle branch block (RBBB) is often seen as harmless and common. However, many studies show it might be linked to negative health outcomes. So, it is crucial to fully understand how RBBB affects the heart's ventricles.

View Article and Find Full Text PDF

Background: A partial atrioventricular septal defect (AVSD) with a hypoplastic left ventricle and common atrium is a rare combination of cardiac anomalies that can be associated with Ellis-van Creveld (EVC) syndrome.

Case Summary: A female neonate with EVC syndrome was diagnosed with an unbalanced AVSD and hypoplastic left ventricle. Pulmonary artery banding and ductus ligation were performed at 23 days after birth.

View Article and Find Full Text PDF

Background: Endothelial function (EndFx) is a core component of cardiovascular (CV) health and cardioprotection following acute myocardial infarction (AMI) treated with primary percutaneous coronary intervention (PCI).

Hypothesis: AMI patients experience endothelial dysfunction (EndDys), associated with traditional CV risk factors and sleep patterns. EndFx may also predict short and mid-term outcomes.

View Article and Find Full Text PDF

Monitoring of perioperative tissue perfusion and impact on patient outcomes.

J Cardiothorac Surg

January 2025

Department of Anesthesiology, Zhongda hospital, Southeast University, No. 87 Dingjiaqiao, Nanjing City, 210009, Jiangsu Province, China.

Monitoring perioperative tissue perfusion is crucial in clinical anesthesia to protect organs and ensure patient safety. Indicators like hemodynamic parameters, tissue metabolism, and microcirculation markers are used for assessment. Studies show intraoperative hypotension negatively impacts outcomes, though blood pressure alone may not reflect tissue perfusion accurately.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!