Bioinspir Biomim
Korea Institute of Ocean Science and Technology, Ansan 426-444, Korea.
Published: July 2015
In this study, we conduct experimental and consecutive numerical analyses of a flapping tidal current generator with a mirror-type dual configuration with front-swing and rear-swing flappers. An experimental analysis of a small-scale prototype is conducted in a towing tank, and a numerical analysis is conducted by means of two-dimensional computational fluid dynamics simulations with an in-house code. An experimental study with a controller to determine the target arm angle shows that the resultant arm angle is dependent on the input arm angle, the frequency, and the applied load, while a high pitch is obtained simply with a high input arm angle. Through a parametric analysis conducted while varying these factors, a high applied load and a high input arm angle were found to be advantageous. Moreover, the optimal reduced frequency was found to be 0.125 in terms of the power extraction. In consecutive numerical investigations with the kinematics selected from the experiments, it was found that a rear-swing flapper contributes to the total amount of power more than a front-swing flapper with a distance of two times the chord length and with a 90° phase difference between the two. The high contribution stems from the high power generated by the rear-swing flapper, which mimics the tail fin movement of a dolphin along a flow, compared to a plunge system or a front-swing system, which mimics the tail fin movement of a dolphin against a flow. It is also due to the fact that the shed vorticities of the front-swing flapper slightly affect negatively or even positively the power performance of the rear-swing system at a given distance and phase angle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1748-3190/10/4/046015 | DOI Listing |
Exp Physiol
January 2025
Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
There is limited knowledge on diffusing capacity in scoliosis patients. It remains to be determined if impaired pulmonary diffusing capacity is mostly influenced by reduced alveolar-capillary membrane diffusing capacity (D), reduced pulmonary capillary blood volume (V) or both. This study aims to report findings from dual test gas pulmonary diffusing capacity for carbon monoxide and nitric oxide (D) with quantification of pulmonary diffusing capacity for carbon monoxide corrected for haemoglobin with a five s breath-hold (D) and nitric oxide with a five s breath-hold (D), D and V.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, Syria.
Twin block appliances are commonly used to treat skeletal class II malocclusion. However, many adverse effects, such as lower incisor protrusion and a bulky nature, can be observed. To overcome these effects, a modified twin block was designed, which uses vacuum-formed hard plates (VFPs) instead of acrylic plates.
View Article and Find Full Text PDFEur Spine J
January 2025
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada.
Purpose: Clinicians monitor scoliosis progression using multiple radiographs during growth. During imaging, arms must be elevated to visualize vertebrae, possibly affecting sagittal alignment. This study aimed to determine the arm position that best represents habitual standing (and possibly allowing hand-based skeletal maturity assessment) to obtain frontal and lateral stereo-radiographs as measured using frontal, sagittal, and transverse angles.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Orthopedic Surgery, Korea University Anam Hospital, Seoul 02841, Republic of Korea.
This study compares clinical and radiological outcomes of open microscopic posterior cervical foraminotomy (PCF) and biportal endoscopic spine surgery (BESS) PCF in multi-level cases. While BESS PCF is effective in single-level surgeries, its role in multi-level procedures remains unclear. : This retrospective cohort study included 60 patients treated for cervical radiculopathy from 2016 to 2023, divided into two groups, open microscopic PCF (Group M, = 30) and BESS PCF (Group B, = 30).
View Article and Find Full Text PDFSensors (Basel)
December 2024
Assessment of Movement Behaviours (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK.
Background: Following shoulder surgery, controlled and protected mobilisation for an appropriate duration is crucial for appropriate recovery. However, methods for objective assessment of sling wear and use in everyday living are currently lacking. In this pilot study, we aim to determine if a sling-embedded triaxial accelerometer and/or wrist-worn sensor can be used to quantify arm posture during sling wear and adherence to sling wear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.