The ex situ lift out (EXLO) adhesion forces are reviewed and new applications of EXLO for focused ion beam (FIB)-prepared specimens are described. EXLO is used to manipulate electron transparent specimens on microelectromechanical systems carrier devices designed for in situ electron microscope analysis. A new patented grid design without a support film is described for EXLO. This new slotted grid design provides a surface for holding the specimen in place and also allows for post lift out processing. Specimens may be easily manipulated into a backside orientation to reduce FIB curtaining artifacts with this slotted grid. Large EXLO specimens can be manipulated from Xe+ plasma FIB prepared specimens. Finally, applications of EXLO and manipulation of FIB specimens using a vacuum probe lift out method are shown. The vacuum probe provides more control for placing specimens on the new slotted grids and also allows for easy manipulation into a backside configuration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/S1431927615013720 | DOI Listing |
Microsc Microanal
January 2025
EXpressLO LLC, 5483 Lee St Unit 12, Lehigh Acres, FL 33971, USA.
A conduction heat transfer analysis of ex situ lift-out specimen handling under cryogenic conditions (cryo-EXLO) is performed and compared with experimentally determined temperature values using a type K thermocouple. Using a finite-volume solver for heat conduction, the analysis confirms that manipulation of a specimen by a probe above a working surface cooled at liquid nitrogen (LN2) temperatures can remain below the critical vitreous temperature up to several hundreds of micrometers above the working surface, allowing for ample distance for lift out and specimen manipulation. In addition, the temperature above the cryogenic shuttle sample holder working surface remains below the vitreous temperature for several tens of minutes without adding cryogen, yielding sufficient time to complete multiple manipulations.
View Article and Find Full Text PDFBiochem Soc Trans
December 2024
Research Group CryoEM Technology, Max Planck Institute of Biochemistry, Martinsried, Germany.
Cryo-electron tomography (cryo-ET) has become a key technique for obtaining structures of macromolecular complexes in their native environment, assessing their local organization and describing the molecular sociology of the cell. While microorganisms and adherent mammalian cells are common targets for tomography studies, appropriate sample preparation and data acquisition strategies for larger cellular assemblies such as tissues, organoids or small model organisms have only recently become sufficiently practical to allow for in-depth structural characterization of such samples in situ. These advances include tailored lift-out approaches using focused ion beam (FIB) milling, and improved data acquisition schemes.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
The Department of Medical Imaging, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou, 518037, P. R. China.
Cancer metastasis remains a critical factor contributing to the current limitations in cancer treatment. Photothermal immunotherapy has emerged as a safe and potent therapeutic approach, demonstrating the capability to suppress tumor growth and metastasis. While researchers have extensively investigated various structural modifications to enhance photothermal conversion performance, the influence of molecular configuration has received comparatively limited attention.
View Article and Find Full Text PDFAdv Mater
January 2025
College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, P. R. China.
Lithography is critical in micro- and nanofabrication processes, enabling the development of integrated circuits, semiconductor devices, and various advanced electronic and photonic systems. However, there are challenges related to sustainability, efficiency, and yield, as well as compatibility with transient electronics. This work introduces a sustainable lithography paradigm employing mechanically peelable resists compatible with existing cleanroom processes.
View Article and Find Full Text PDFWater Res
January 2025
Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China. Electronic address:
The presence of 2-methylisoborneol (2-MIB) is acknowledged as a prevalent source of odor-related challenges in drinking water reservoirs. Among the three in situ experiments conducted in drinking water reservoir, the water-lifting aerator with bio-filling system exhibited the most pronounced overall effects. It achieved a remarkable 98.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!