Aim: To conduct a systematic review of management of current cephalic arch stenosis (CAS) and associated outcomes in the context of dysfunctional hemodialysis access.

Materials And Methods: PubMed, Web of Science, and Cochrane Library were searched to retrieve literature on the management of CAS. Studies had to focus on management of access stenosis solely in the cephalic arch. Case reports and literature reviews were excluded. Studies were categorized by intervention, and primary and secondary patency data were compiled. Studies were aggregated, and meta-analyses were performed where possible.

Results: Nine papers satisfied the aforementioned criteria: five were retrospective studies and four were prospective studies. CAS management strategies have included percutaneous transluminal balloon angioplasty (PTA), peripheral cutting balloons, surgical cephalic vein transpositions, bare stents, and stent grafts. Reporting strategies varied between studies. Meta-analyses showed that results were variable even within studies using the same modality, particularly for PTA.

Conclusion: No singular, definitive management strategy exists for CAS. Current studies are limited by being primarily single-center retrospective trials featuring heterogenous patient populations, interventions, and endpoints. Priorities for future studies should include larger randomized trials, more uniform management strategies and endpoints, and a longer duration of follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-015-1190-4DOI Listing

Publication Analysis

Top Keywords

cephalic arch
12
studies
9
arch stenosis
8
systematic review
8
management strategies
8
management
7
management cephalic
4
stenosis arteriovenous
4
arteriovenous fistulas
4
fistulas hemodialysis
4

Similar Publications

Chondrocutaneous Custom-made Graft for Upper Lateral and Alar Cartilage Nose Reconstruction: The T Graft.

Arch Plast Surg

January 2025

Department of Experimental and Clinical Medicine, Clinic of Plastic and Reconstructive Surgery, Marche Polytechnic University Medical School, Ancona, Italy.

Upper lateral cartilage and alar cartilage nose reconstruction secondary to failed aesthetic procedure or tumor excision, surely represents a reconstructive challenge for plastic surgeons, because of the support needed and for the function of the internal nasal valve (INV). Several scientific publications deal with internal nasal reconstructive techniques, including simple homologous or heterologous tissue grafts. We describe a new hybrid chondrocutaneous graft used for reconstruction of the upper lateral cartilage and a portion of the alar cartilage (cephalic part), excised with the adherent nasal mucosa (in correspondence with INV), included in the tumor mass.

View Article and Find Full Text PDF

The first cervical vertebra (C1) is atypical in shape and bears a complex relationship with important neurovascular structures such as the vertebral artery and cervical spinal cord which are at risk of injury during misplaced screw fixation of C1. Placement of screws into the lateral mass of C1 vertebra is performed for stabilization of the craniovertebral junction. The objective of this study was to describe ideal screw dimensions, precise entry points, safe bony corridors, and ideal trajectories for placement of lateral mass screws in the Emirati population.

View Article and Find Full Text PDF

Purpose: The AVeNEW Post-Approval Study (AVeNEW PAS) follows upon results from the AVeNEW IDE clinical trial and was designed to provide additional clinical evidence of safety and effectiveness using the Covera™ Vascular Covered Stent to treat arteriovenous fistula (AVF) stenoses in a real-world hemodialysis patient population.

Materials And Methods: One hundred AVF patients were prospectively enrolled at 11 clinical trial sites in the USA and treated with the covered stent after angioplasty of a clinically significant target stenosis. The primary safety outcome was freedom from any adverse event that suggests the involvement of the AV access circuit evaluated at 30 days.

View Article and Find Full Text PDF

Objective: To determine whether patients undergoing a trial of labor with a breech presentation following a failed attempt of external cephalic version (ECV) are at increased risk of adverse maternal and neonatal outcomes.

Methods: This retrospective cohort study was conducted at a single university-affiliated medical center. The study group comprised women with singleton pregnancies at term, categorized into three groups: those who underwent a failed external cephalic version (ECV) and subsequently attempted a trial of breech delivery (Breech-failed-ECV group), those who attempted an assisted vaginal breech delivery without a prior ECV attempt (Breech-no-ECV group), and those with vertex presentation following a successful ECV (Vertex-ECV).

View Article and Find Full Text PDF

Purpose: The PowerGlide Pro™ Midline Catheter is a peripheral venous access device with a length of 8-10 cm, allowing the tip to reach far into the venous system. The aim of this study was to evaluate the dwell time of the catheter. Secondary endpoints included suitability for specific medications (e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!