A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Value of Rotational Venography Versus Anterior-Posterior Venography in 100 Consecutive IVC Filter Retrievals. | LitMetric

The Value of Rotational Venography Versus Anterior-Posterior Venography in 100 Consecutive IVC Filter Retrievals.

Cardiovasc Intervent Radiol

Division of Interventional Radiology, Department of Radiology, Hospital of University of Pennsylvania Medical Center, 1 Silverstein, 3400 Spruce St., Philadelphia, PA, 19104, USA.

Published: March 2016

Purpose: Accurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior-posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.

Materials And Methods: The rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tip embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.

Results: Using operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59%). AP venography was used to correctly identify 31 tip-embedded filters (53% sensitivity) with two false positives (95% specificity) for an accuracy of 70%. Rotational venography was used to correctly identify 58 tip-embedded filters (98% sensitivity) with one false positive (98% specificity) for an accuracy of 98%. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.

Conclusion: Rotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-015-1183-3DOI Listing

Publication Analysis

Top Keywords

ivc filter
24
rotational venography
12
tip-embedded filters
12
prior ivc
12
rotational venograms
12
filter
9
100 consecutive
8
ivc
8
consecutive ivc
8
filter retrievals
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!