Introduction: Traditional open exposure for posterior instrumentation requires significant soft tissue mobilization and causes significant blood loss and increased recovery time. Mal-placed screws can injure nerve roots, the spinal cord, viscera, vasculature and the cardiopulmonary system. Placement of pedicle screws using a minimally invasive technique can decrease bleeding risk, damage to soft tissues, and post-operative pain. The purpose of this study is to compare the radiographic accuracy of open free-hand versus percutaneous technique for pedicle screw placement.

Methods: Consecutive patients undergoing thoracolumbar surgery from September 2006 to October 2011 with post-operative CT imaging were included in this study. Three-dimensional screw positioning within the pedicle and the vertebral body was assessed on CT. The magnitude and location of violations were measured and recorded. Facet breaches at the cephalad and caudad ends of the construct were documented and graded.

Results: Two-hundred and twenty-three patients met the inclusion criteria for a total of 1609 pedicle screws. Seven-hundred and twenty-four screws were placed using a standard open free-hand technique and 885 were placed percutaneously. There was a significant difference in overall pedicle breach rates: 7.5 % for open and 4.7 % for percutaneous techniques. The magnitude of breach was greater for the percutaneous technique compared to the open technique: 5.4 versus 3.7 mm, respectively. The difference in vertebral body breaches was also significant: 11.3 % for open and 3.6 % for percutaneous. The rates of facet breach did not significantly differ.

Discussion And Conclusion: This is the largest series comparing the accuracy of percutaneous to open pedicle screw placement. The rates of pedicle, vertebral body, and facets breaches in the percutaneous group were similar to the rates in the open technique group as well as rates reported in the literature. This demonstrates that the percutaneous technique described here is an accurate alternative to standard open free-hand technique.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-015-4163-zDOI Listing

Publication Analysis

Top Keywords

pedicle screw
12
open free-hand
12
percutaneous technique
12
vertebral body
12
open
10
accuracy percutaneous
8
pedicle
8
open pedicle
8
pedicle screws
8
technique
8

Similar Publications

Objective: When creating minimally invasive spine fusion constructs, accurate pedicle screw fixation is essential for biomechanical strength and avoiding complications arising from delicate surrounding structures. As research continues to analyze how to improve accuracy, long-term patient outcomes based on screw accuracy remain understudied. The objective of this study was to analyze long-term patient outcomes based on screw accuracy.

View Article and Find Full Text PDF

Introduction: As medical education becomes more complex, the demand for advanced teaching and training methods has grown. Technological advancements have opened up new possibilities, particularly in the realm of virtual reality (VR) simulations for training.

Research Question: Our prospective, randomized pilot study aims to assess whether a novel VR-based 3D training platform can effectively teach the knowledge and skills needed for complex spinal surgery, specifically pedicle screw placement.

View Article and Find Full Text PDF

Purpose: To describe a novel alternative technique for C2 fixation under the concept of atlantoaxial joint distraction and fusion with intra-articular Cages, and to report its preliminary clinical outcomes.

Methods: Eighteen patients with basilar invagination and atlantoaxial dislocation underwent atlantoaxial joint distraction and fusion with intra-articular Cages. All patients had hypoplasia of the C2 isthmus prohibiting insertion of the pedicle screw.

View Article and Find Full Text PDF

Background: Comparative studies of posterior lumbar interbody fusion with cortical bone trajectory and pedicle screw in older patients, particularly in those aged ≥ 80 years, are rare. This study aimed to retrospectively analyze the clinical and surgical outcomes following posterior lumbar interbody fusion with pedicle screw fixation compared to cortical bone trajectory in patients aged ≥ 80 years with degenerative lumbar spine disease.

Methods: We included 68 patients aged ≥ 80 years who underwent degenerative lumbar spinal surgery at our spine center between January 2011 and December 2020.

View Article and Find Full Text PDF

Spine surgery is highly litigious; misplaced screws and intraoperative neuromonitoring frequently feature in lawsuits. Intraoperative neuromonitoring aims to prevent injury but its standards are debated, and literature suggests its benefits are mixed. We surveyed its use among neurosurgeons from the Congress of Neurological Surgeons with Pearson's chi-square test applied to analyse data within R.

View Article and Find Full Text PDF