A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Parameters affecting different acoustic radiation force impulse applications in the diagnosis of fibrotic liver changes. | LitMetric

Parameters affecting different acoustic radiation force impulse applications in the diagnosis of fibrotic liver changes.

World J Gastroenterol

Sabrina Galgenmueller, Wolfgang Kratzer, Suemeyra Oeztuerk, Mark M Haenle, Department of Internal Medicine I, University Hospital Ulm, 89081 Ulm, Germany.

Published: July 2015

Aim: To analyze the virtual touch tissue quantification (VTTQ) and virtual touch imaging quantification (VTIQ) techniques, and identify possible factors that may influence VTTQ and VTIQ measurements.

Methods: One hundred and eighty-six (104 women/82 men) of 323 subjects met the inclusion criteria (age > 18 years, no history of chronic or gastrointestinal disease, body-mass index (BMI) < 30 kg/m², a fasting period of at least three hours, no history of hepatotoxic pharmaceuticals, alcohol consumption < 24 g/d in men and < 12 g/d in women, and normal findings upon ultrasound examination of the abdomen). Measurements were taken at depths of 50 mm with VTTQ, 15 mm and 25 mm with VTIQ in the right hepatic lobe, and at 15 mm with only VTIQ in the left hepatic lobe. The examiner acquired six measurements per position, thereby giving 24 measurements in total.

Results: The 95% confidence intervals of mean were 1.23-1.29 m/s for VTTQ and 1.29-1.37 m/s, 1.17-1.23 m/s, and 1.48-1.57 m/s for VTIQ in a depth of 15 mm and 25 mm in the right hepatic lobe and 15 mm in the left hepatic lobe. Only superficial measurements in the right hepatic lobe with the VTIQ method exhibited an effect of age on shear wave velocity. Measurements acquired using the 6C1 probe with the VTTQ method showed no dependence on BMI. By comparison, BMI influenced measurements taken with the VTIQ method using the 9L4 probe in the superficial and deep areas of the right hepatic lobe, as well as in the left hepatic lobe (P = 0.0160, P = 0.0019, P = 0.0173, respectively). Gender influenced measurements at depths of 50 mm with VTTQ and 25 mm with VTIQ in the right hepatic lobe (P = 0.0001, P = 0.0269). Significant differences were found between measurements with the 6C1 (VTTQ) and 9L4 probes (VTIQ) (P = 0.0067), between superficial and deep measurements (P < 0.0001), and between the right and left lobes of the liver (P < 0.0001).

Conclusion: Measurements in the right lobe and deep regions are preferable. Gender differences must be considered. BMI must be considered when assessing VTIQ technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4507113PMC
http://dx.doi.org/10.3748/wjg.v21.i27.8425DOI Listing

Publication Analysis

Top Keywords

hepatic lobe
32
vttq vtiq
12
left hepatic
12
vtiq
10
measurements
10
lobe
9
virtual touch
8
measurements depths
8
depths vttq
8
hepatic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!