Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The incidence of new or worsening tricuspid regurgitation (TR) or mitral regurgitation (MR) after permanent pacemaker (PPM) or implantable cardioverter defibrillator (ICD) lead placement has not been well investigated. We studied the effect of transvenous leads implantation and right ventricular (RV) pacing on tricuspid and mitral valve regurgitations.
Methods: We reviewed the charts of all patients undergoing PPM or ICD lead placement in our electrophysiology laboratory from December 2001 to December 2006.
Results: A total of 206 patients (120 with PPM and 86 with ICD) had baseline echocardiography within 6months before, and a follow up study at least 6months after lead insertion. The mean age was 74±14years; 56% were men. The follow-up period was 29±19months. TR worsened by at least one grade after lead insertion in 44.7% patients (P<0.001). Pre- and post-implant changes in TR severity did not differ with respect to lead type (ICD vs. PPM) or degree of RV pacing dependence. As for MR; patients with high frequency of RV pacing (>40%) had a higher incidence of worsening MR when compared to those with low frequency of RV pacing (44% vs. 19%; P<0.001).
Conclusion: PPM or ICD lead implantation worsens TR; that effect is probably induced by mechanical interferences with the TV closure and was consistent regardless the lead type or degree of RV Pacing. MR was noted to increase in patients with high frequency of RV pacing frequency; this is probably caused by the mechanical dyssynchrony induced by RV pacing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelectrocard.2015.07.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!