Accuracy of 3 different impression techniques for internal connection angulated implants.

J Prosthet Dent

Professor and Chairman, Department of Fixed Prosthesis and Implant Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece. Electronic address:

Published: October 2015

Statement Of Problem: Making implant impressions with different angulations requires a more precise and time-consuming impression technique.

Purpose: The purpose of this in vitro study was to compare the accuracy of nonsplinted, splinted, and snap-fit impression techniques of internal connection implants with different angulations.

Material And Methods: An experimental device was used to allow a clinical simulation of impression making by means of open and closed tray techniques. Three different impression techniques (nonsplinted, acrylic-resin splinted, and indirect snap-fit) for 6 internal-connected implants at different angulations (0, 15, 25 degrees) were examined using polyether. Impression accuracy was evaluated by measuring the differences in 3-dimensional (3D) position deviations between the implant body/impression coping before the impression procedure and the coping/laboratory analog positioned within the impression, using a coordinate measuring machine. Data were analyzed by 2-way ANOVA. Means were compared with the least significant difference criterion at P<.05.

Results: Results showed that at 25 degrees of implant angulation, the highest accuracy was obtained with the splinted technique (mean ±SE: 0.39 ±0.05 mm) and the lowest with the snap-fit technique (0.85 ±0.09 mm); at 15 degrees of angulation, there were no significant differences among splinted (0.22 ±0.04 mm) and nonsplinted technique (0.15 ±0.02 mm) and the lowest accuracy obtained with the snap-fit technique (0.95 ±0.15 mm); and no significant differences were found between nonsplinted and splinted technique at 0 degrees of implant placement.

Conclusions: Splinted impression technique exhibited a higher accuracy than the other techniques studied when increased implant angulations at 25 degrees were involved.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2015.05.005DOI Listing

Publication Analysis

Top Keywords

impression techniques
12
techniques internal
8
internal connection
8
impression
7
accuracy impression
4
techniques
4
connection angulated
4
angulated implants
4
implants statement
4
statement problem
4

Similar Publications

Sildenafil is one of the most used phosphodiesterase type 5 inhibitor (PDE5i) for the treatment of erectile dysfunction (ED) in clinical practice. A new oral suspension formulation (OSF) of sildenafil has been introduced to overcome the drawbacks of previous formulations. We assess the efficacy and patients' experience with sildenafil 50 mg OSF in men with ED who were taking the sildenafil oro-dispersible film (ODF).

View Article and Find Full Text PDF

Design: A triple-armed, double-blind randomized controlled trial with cross-over design investigated patient-reported satisfaction and objective dental evaluation of a 3-unit, monolithic zirconium dioxide (ZrO2), implant-supported fixed dental prosthesis (iFDP) fabricated with 2 completely digital workflows and 1 mixed analog-digital workflow.

Case Selection: Participants enrolled required rehabilitation of 2 dental implants in posterior region of either of the arches with a 3-unit, ZrO2 iFDP. A total of 20 participants received the 3 types of ZrO2, iFDP fabricated by 3 different methods.

View Article and Find Full Text PDF

Diagnostic cholangioscopy for surgical planning of extrahepatic cholangiocarcinoma.

Sci Rep

January 2025

Digestive Disease Center, CHA Bundang Medical Center, CHA University School of Medicine, 59 Yatap-ro, Seongnam-si, 13496, Gyeonggi-do, Republic of Korea.

The recent clinical outcomes of multi-regimen chemotherapy included prolonged survival and a high rate of conversion to surgery in Asian patients with advanced biliary tract cancer. The ability of single-operator cholangioscopy (SOC) to detect and stage extrahepatic cholangiocarcinoma (CCC) in intraductal lesions is becoming more important in determining the extent of surgery. The aim of this study was to evaluate the role of SOC in surgical planning for extrahepatic CCC.

View Article and Find Full Text PDF

Purpose: To explore the perceived utility and effect of simplified radiology reports on oncology patients' knowledge and feasibility of large language models (LLMs) to generate such reports.

Materials And Methods: This study was approved by the Institute Ethics Committee. In phase I, five state-of-the-art LLMs (Generative Pre-Trained Transformer-4o [GPT-4o], Google Gemini, Claude Opus, Llama-3.

View Article and Find Full Text PDF

Reviews of the effectiveness of medicinal cannabis for chronic pain vary in their conclusions. IASP has identified that a key missing evidence in this debate is data from observational cohort studies, analyzed with comparative effectiveness methods. In a medically supervised context to the use of marijuana for chronic pain, we identified 440 patients certified for medical marijuana by pain specialists in a single healthcare system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!