Background: Estimation of the infarct size from body-surface ECGs in post-myocardial infarction patients has become possible using the Selvester scoring method. Automation of this scoring has been proposed in order to speed-up the measurement of the score and improving the inter-observer variability in computing a score that requires strong expertise in electrocardiography. In this work, we evaluated the quality of the QuAReSS software for delivering correct Selvester scoring in a set of standard 12-lead ECGs.
Method: Standard 12-lead ECGs were recorded in 105 post-MI patients prescribed implantation of an implantable cardiodefibrillator (ICD). Amongst the 105 patients with standard clinical left bundle branch block (LBBB) patterns, 67 had a LBBB pattern meeting the strict criteria. The QuAReSS software was applied to these 67 tracings by two independent groups of cardiologists (from a clinical group and an ECG core laboratory) to measure the Selvester score semi-automatically. Using various level of agreement metrics, we compared the scores between groups and when automatically measured by the software.
Results: The average of the absolute difference in Selvester scores measured by the two independent groups was 1.4±1.5 score points, whereas the difference between automatic method and the two manual adjudications were 1.2±1.2 and 1.3±1.2 points. Eighty-two percent score agreement was observed between the two independent measurements when the difference of score was within two point ranges, while 90% and 84% score agreements were reached using the automatic method compared to the two manual adjudications.
Conclusion: The study confirms that the QuAReSS software provides valid measurements of the Selvester score in patients with strict LBBB with minimal correction from cardiologists.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelectrocard.2015.06.003 | DOI Listing |
J Electrocardiol
February 2019
Department of Cardiology, Clinical Sciences, Lund University, Sweden; Arrythmia Clinic, Scania University Hospital, Lund, Sweden.
Background: Cardiac Resynchronization Therapy (CRT) is widely used for treating selected heart failure patients, but patients with myocardial scar respond worse to treatment. The Selvester QRS scoring system estimates myocardial scar burden using 12-lead ECG. This study's objective was to investigate the scores correlation to mortality in a CRT population.
View Article and Find Full Text PDFJ Electrocardiol
June 2016
Heart Research Follow-Up Program, University of Rochester, NY, USA.
Background: Estimation of the infarct size from body-surface ECGs in post-myocardial infarction patients has become possible using the Selvester scoring method. Automation of this scoring has been proposed in order to speed-up the measurement of the score and improving the inter-observer variability in computing a score that requires strong expertise in electrocardiography. In this work, we evaluated the quality of the QuAReSS software for delivering correct Selvester scoring in a set of standard 12-lead ECGs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!