Introduction: To evaluate the accuracy of CAD/CAM generated splints in orthognathic surgery by comparing planned versus actual post-operative 3D images.

Methods: Specific planning software (SimPlant(®) OMS Standalone 14.0) was used to perform a 3D virtual Le Fort I osteotomy in 10 fresh human cadaver heads. Stereolithographic splints were then generated and used during the surgical procedure to reposition the maxilla according to the planned position. Pre-operative planned and postoperative 3D CT scan images were fused and imported to dedicated software (MATLAB(®)) 7.11.) for calculating the translational and rotational (pitch, roll and yaw) differences between the two 3D images. Geometrical accuracy was estimated using the Root Mean Square Deviations (RMSD) and lower and upper limits of accuracy were computed using the Bland & Altman method, with 95 % confidence intervals around the limits. The accuracy cutoff was set at +/- 2 mm for translational and ≤ 4° for rotational measurements.

Results: Overall accuracy between the two 3D images was within the accuracy cutoff for all values except for the antero-posterior positioning of the maxilla (2.17 mm). The translational and rotational differences due to the splint were all within the accuracy cutoff. However, the width of the limits of agreement (range between lower and upper limits) showed that rotational differences could be particularly large.

Conclusion: This study demonstrated that maxillary repositioning can be accurately approximated and thus predicted by specific computational planning and CAD/CAM generated splints in orthognathic surgery. Further study should focus on the risk factors for inaccurate prediction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4514936PMC
http://dx.doi.org/10.1186/s13005-015-0082-9DOI Listing

Publication Analysis

Top Keywords

cad/cam generated
12
generated splints
12
splints orthognathic
12
orthognathic surgery
12
accuracy cutoff
12
accuracy
8
translational rotational
8
lower upper
8
upper limits
8
limits accuracy
8

Similar Publications

Background: Bibliometric analyses of software applications in plastic surgery are relatively limited. This study aims to address this gap by summarizing current research trends and providing insights that may guide future developments in this field.

Methods: Data were retrieved from the Web of Science Core Collection.

View Article and Find Full Text PDF

Metabolic dysfunction-associated steatohepatitis (MASH), formerly known as nonalcoholic steatohepatitis (MASH), is a major risk factor for cirrhosis and hepatocellular carcinoma (HCC) and a leading cause of liver transplantation. MASH is caused by an accumulation of toxic fat molecules in the hepatocyte which leads to inflammation and fibrosis. Inadequate human "MASH in a dish" models have limited our advances in understanding MASH pathogenesis and in drug discovery.

View Article and Find Full Text PDF

Effect of different restorative design and materials on stress distribution in cracked teeth: a finite element analysis study.

BMC Oral Health

January 2025

Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.

Objectives: To compare the stress distribution and crack propagation in cracked mandibular first molar restored with onlay, overlay, and two types of occlusal veneers using two different CAD/CAM materials by Finite Element Analysis (FEA).

Materials And Methods: A mandibular first molar was digitized using a micro CT scanning system in 2023. Three-dimensional dynamic scan data were transformed, and a 3D model of a cracked tooth was generated.

View Article and Find Full Text PDF

Objective: To analyze the early- to mid-term clinical efficacy of personalized 3D-printed structural metal spacer technology in reconstructing massive bone defects during complex total knee arthroplasty (TKA) and revision surgery.

Methods: A single-center retrospective study was conducted on nine patients with severe bone defects who underwent TKA between 2018 and 2024. The general condition, surgical details, and clinical improvement of these patients were recorded and analyzed by clinical doctors.

View Article and Find Full Text PDF

Computer-Aided Design to Improve the Thermal Stability of Lipase.

Foods

December 2024

State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China.

Lipase, a green biocatalyst, finds extensive application in the food sector. Enhancing the thermal stability of lipase presents both challenges and opportunities within the food industry. This research employed multiple rounds of cross-screening using tools like FoldX and I-Mutant 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!