Partial loss and subsequent recovery of cochlear implant function in the first few weeks following cochlear implant surgery has been observed in previous studies using psychophysical detection thresholds. In the current study, we explored this putative manifestation of insertion trauma using objective functional measures: electrically-evoked compound action potential (ECAP) amplitude-growth functions (ECAP amplitude as a function of stimulus level). In guinea pigs implanted in a hearing ear with good post-implant hearing and good spiral ganglion neuron (SGN) survival, consistent patterns of ECAP functions were observed. The slopes of ECAP growth functions were moderately steep on the day of implant insertion, decreased to low levels over the first few days after implantation and then increased slowly over several weeks to reach a relatively stable level. In parallel, ECAP thresholds increased over time after implantation and then recovered, although more quickly, to a relatively stable low level as did thresholds for eliciting a facial twitch. Similar results were obtained in animals deafened but treated with an adenovirus with a neurotrophin gene insert that resulted in good SGN preservation. In contrast, in animals implanted in deaf ears that had relatively poor SGN survival, ECAP slopes reached low levels within a few days after implantation and remained low. These results are consistent with the idea that steep ECAP growth functions require a healthy population of auditory nerve fibers and that cochlear implant insertion trauma can temporarily impair the function of a healthy SGN population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4674315 | PMC |
http://dx.doi.org/10.1016/j.heares.2015.07.010 | DOI Listing |
J Vis Exp
December 2024
Department of General Surgery (Hepatobiliary, Pancreatic and Splenic Surgery), The Sixth Affiliated Hospital, Sun Yat-sen University; Biomedical Innovation Center, The Sixth Affiliated Hospital, Sun Yat-sen University;
Robot-assisted pancreaticobiliary junction resection is a surgical technique employed to treat benign duodenal tumors. The procedure involves several key steps: making a longitudinal incision in the duodenum, excising the tumor at the pancreaticobiliary junction, inserting a biliary stent, connecting the biliary and duodenal mucosa, and suturing the duodenal incision during phase I. The robotic system enhances visibility, facilitates precise operations, minimizes duodenal traction injuries to the duodenum and surgical trauma, ensures accurate suture and fixation of bile duct stents, connects the bile duct and duodenal mucosa and reduces postoperative recovery time.
View Article and Find Full Text PDFCureus
December 2024
Student Research Unit, School of Medicine, 21 September University, Sana'a, YEM.
Penetrating thoracic injuries, especially those affecting cardiac structures, are rare but can be life-threatening, requiring urgent medical care. Right atrium injuries pose significant risks, including rapid blood loss, cardiac tamponade, hemodynamic instability, and, subsequently, potential death. We report the case of a 24-year-old male patient with stab wounds leading to a right-sided chest penetration three hours prior to presentation.
View Article and Find Full Text PDFJ Clin Orthop Trauma
January 2025
Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, 2160 South First Avenue, 60153, Maywood, IL, USA.
Introduction: Mobile-bearing (MB) inserts, designed to minimize aseptic loosening and to reduce contact stresses leading to polyethylene wear, are an alternative to fixed-bearing (FB) inserts. Most studies have shown no significant difference between MB and FB constructs, and there is limited long-term data comparing the two constructs [1,2,3,4]. The purpose of this study was to report the outcomes of a randomized controlled trial comparing MB versus FB inserts on patients with minimum 20-year follow-up.
View Article and Find Full Text PDFJ Robot Surg
January 2025
The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.
The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Orthopedics, First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China. Electronic address:
Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.
Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!