Little is known about the effects of tensile forces on osteoclastogenesis by human monocytes in the absence of mechanosensitive cells, including osteoblasts and fibroblasts. In this study we consider the effects of tensile force on osteoclastogenesis in human monocytes. The cells were treated with receptor activator of nuclear factor κB ligand (RANKL) to promote osteoclastogenesis. Then,expression and secretion of cathepsin K were examined. RANKL and the formation of osteoclasts during the osteoclast differentiation process under continual tensile stress were evaluated by Western blot. It was also found that -100 kPa or lower induces RANKL-enhanced tartrate-resistant acid phosphatase activity in a dose-dependent manner. Furthermore, an increased tensile force raises the expression and secretion of cathepsin K elevated by RANKL, and is concurrent with the increase of TNF-receptor-associated factor 6 induction and nuclear factor κB activation. Overall, the current report demonstrates that tensile force reinforces RANKL-induced osteoclastogenesis by retarding osteoclast differentiation. The tensile force is able to modify every cell through dose-dependent in vitro RANKL-mediated osteoclastogenesis, affecting the fusion of preosteoclasts and function of osteoclasts. However, tensile force increased TNF-receptor-associated factor 6 expression. These results are in vitro findings and were obtained under a condition of tensile force. The current results help us to better understand the cellular roles of human macrophage populations in osteoclastogenesis as well as in alveolar bone remodeling when there is tensile stress.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00774-015-0690-2DOI Listing

Publication Analysis

Top Keywords

tensile force
28
tensile
10
human macrophage
8
receptor activator
8
activator nuclear
8
nuclear factor κb
8
factor κb ligand
8
effects tensile
8
osteoclastogenesis human
8
human monocytes
8

Similar Publications

Multiscale Mechanical Study of Proanthocyanidins for Recovering Residual Stress in Decellularized Blood Vessels.

Adv Healthc Mater

January 2025

Key Laboratory of Biorheological Science and Technology (Chongqing University), Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, College of Bioengineering, Chongqing, 400044, P. R. China.

Decellularized artificial blood vessels prepared using physical and chemical methods often exhibit limitations, including poor mechanical performance, susceptibility to inflammation and calcification, and reduced patency. Cross-linking techniques can enhance the stiffness, as well as anti-inflammatory and anti-calcification properties of decellularized vessels. However, conventional cross-linking methods fail to effectively alleviate residual stress post-decellularization, which significantly impacts the patency and vascular remodeling following the implantation of artificial vessels.

View Article and Find Full Text PDF

Incomplete tendon healing and postponed muscle weakness after Achilles tendon rupture and surgical repair lead to poor performance in patient activities. Although the effectiveness of postoperative early functional rehabilitation has been proven, the priority and each effect of specific methods in early rehabilitation remain unclear. We hypothesized early muscle contraction exercises without joint motion would promote tendon healing and prevent calf muscle atrophy; in contrast, early static stretching after surgical repair would not contribute to tendon healing and induce calf muscle atrophy.

View Article and Find Full Text PDF

Mechanical analysis of cerclage as a treatment for cervical insufficiency.

Arch Gynecol Obstet

January 2025

Department of Obstetrics and Gynecology, Ulsan University Hospital, University of Ulsan, College of Medicine, 25 Daehakbyeongwon-ro, Dong-gu, Ulsan, 44033, South Korea.

Background: The primary treatment for cervical insufficiency is cervical cerclage (mechanical support) with vaginal progesterone (biochemical support). Cerclage is a surgical procedure that mechanically increases the tensile capacity of the cervix. Therefore, it is necessary to analyse the effects of cerclage from a mechanical point of view.

View Article and Find Full Text PDF

The present paper investigates the possibility of replacing the traditional L-type corner joint used in chair construction with a 3D printed connector, manufactured using the Fused Filament Fabrication (FFF) method and black PLA as filament. The connector was designed to assemble the legs with seat rails and stretchers, and it was tested under diagonal tensile and compression loads. Its performance was compared to that of the traditional mortise-and-tenon joint.

View Article and Find Full Text PDF

Obtaining reliable dynamic mechanical properties through experiments is essential for developing and validating constitutive models in material selection and structural design. This study introduces a dynamic tensile method using a modified M-type specimen loaded by a split Hopkinson pressure bar (SHPB). A closed M-type specimen was thus employed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!