Animal studies have shown that shock wave lithotripsy (SWL) delivered with an initial course of low-energy shocks followed by a pause reduces renal injury. The pause correlates with increased arterial resistive index (RI) during SWL as measured by ultrasound. This suggests that renal vasoconstriction is associated with protecting the kidney from injury. This study explored whether a similar increase in RI is observed in humans. Patients were prospectively recruited from two hospitals. All received an initial dose of 250 lowest energy shocks followed by a two-minute pause. Shock power was then ramped up at the discretion of the physician; shock rate was maintained at 1 Hz. Spectral Doppler velocity measurements were taken from an interlobar artery at baseline after induction, during the pause at 250 shocks, after 750 shocks, after 1500 shocks, and at the end of the procedure. RI was calculated from the peak systolic and end diastolic velocities and a linear mixed-effects model was used to compare RIs. The statistical model accounted for age, gender, laterality, and body mass index (BMI). Measurements were taken from 15 patients. Average RI ± standard deviation pretreatment, after 250 shocks, after 750 shocks, after 1500 shocks, and post treatment was 0.68 ± 0.06, 0.71 ± 0.07, 0.73 ± 0.06, 0.75 ± 0.07 and 0.75 ± 0.06, respectively. RI was found to be significantly higher after 250 shocks compared to pretreatment (p = 0.04). RI did not correlate with age, gender, BMI, or treatment side. This is suggestive that allowing a pause for renal vascular vasoconstriction to develop may be beneficial, and can be monitored for during SWL, providing real-time feedback as to when the kidney is protected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4507567PMC
http://dx.doi.org/10.1109/ULTSYM.2014.0248DOI Listing

Publication Analysis

Top Keywords

250 shocks
12
shocks
9
shocks 750
8
750 shocks
8
shocks 1500
8
1500 shocks
8
age gender
8
pause
6
shockwave lithotripsy
4
lithotripsy renoprotective
4

Similar Publications

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Background: Hemorrhage and traumatic brain injury (TBI) are the leading causes of death in trauma. Future military conflicts are likely to be in austere environments, where prolonged damage-control resuscitation (p-DCR) may be required for 72 hours before evacuation. Previous studies showed that early administration of fresh frozen plasma (FFP) during p-DCR can significantly decrease the volume of resuscitation required in models of hemorrhagic shock and also provide neuroprotection after TBI.

View Article and Find Full Text PDF

Introduction: While balanced blood component therapy (BCT) is pivotal in trauma patient damage control resuscitation in well-resourced settings, disasters, and mass casualty incidents (MCIs) pose significant challenges, especially in securing sufficient access to blood products. This systematic review and meta-analysis aim to explore the utilization of fresh whole blood (FWB) transfusion as a potential alternative to BCT, informing future research and clinical strategies.

Methods: We searched Pubmed, MEDLINE, Embase, CINAHL, the Cochrane Library and grey literature for articles identifying FWB transfusions, limited to those published in English or French.

View Article and Find Full Text PDF

Background: Infective endocarditis (IE) poses significant risks following percutaneous pulmonary valve implantation (PPVI) or surgical replacement (PVR).

Aims: This study evaluates the effectiveness of emergency percutaneous treatment in stabilizing patients with severe right ventricular dysfunction or obstructive cardiac shock, allowing for delayed surgical or percutaneous valve replacement.

Methods: This retrospective study examines 16 patients (age 19.

View Article and Find Full Text PDF

Aims: Cardiogenic shock (CS) is a critical manifestation of severe cardiac dysfunction, necessitating precise evaluation of left ventricular function by transthoracic echocardiography. The prognostic value of global longitudinal strain (GLS) has not been examined in patients with CS. Therefore, we aimed to assess the prognostic significance of GLS in patients with CS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!