It is widely accepted that an efficient oxygen supply and removal of CO2 in small flying insects are sufficiently performed by diffusion with open spiracles. This paper shows that in the tethered flying blowfly, gas exchange occurs by autoventilation and unidirectional airflow. The air is inspired through the mesothoracic spiracles (Sp1) during the downstroke of the wings and is expired through the metathoracic spiracles (Sp2) during the upstroke. This directed airflow through the thoracic tracheal system was documented by pre-atrial pressure measurements at the Sp1 and Sp2, revealing a sub-atmospheric mean pressure at the Sp1 and an over-atmospheric mean pressure at the Sp2. In the mesothoracic air sacs, the mean pressure is sub-atmospheric, conditioned by the only slightly open spiracles. In a split flow-through chamber experiment, the CO2 released through the Sp2 confirmed this unidirectional respiratory gas flow, implicating an inner tracheal valve. In the thoracic tracheal system, the PO2  during flight exceeds the high resting PO2  by 1-2 kPa, reaching nearly atmospheric values. In the abdominal large air sacs, the PO2  drops during flight, probably due to the accumulation of CO2. Periodic heartbeat reversals continue during flight, with a higher period frequency than at rest, supporting the transport of CO2 via the haemolymph towards the metathoracic tracheae and abdominal air sacs.

Download full-text PDF

Source
http://dx.doi.org/10.1242/jeb.121061DOI Listing

Publication Analysis

Top Keywords

air sacs
12
open spiracles
8
thoracic tracheal
8
tracheal system
8
flight-motor-driven respiratory
4
respiratory airflow
4
airflow increases
4
tracheal
4
increases tracheal
4
tracheal oxygen
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!