An intensive use of the bicycle may increase the risk of erectile dysfunction and the compression of the perineal area has been showed to be a major mechanism leading to sexual alterations compromising the quality of life. Manufacturers claim that pads contribute to increase cyclists perineal protection ensuring a high level of comfort. To investigate the influence of various cycling pads with regard to perineal protection and level of comfort. Nine club road cyclists rode 20 min on a drum simulator, located at the Nutrition and Exercise Physiology Laboratory, at a constant speed and gear ratio wearing the shorts with 3 cycling pads of different design and thickness: basic (BAS), intermediate (INT), and endurance (END). Kinematics and pressure data were recorded at min 5, 15, and 20 of the test using a motion capture system and a pressure sensor mat. The variables of interest were: 3-dimensional pelvis excursions, peak pressure, mean pressure, and vertical force. The comfort level was assessed with a ranking order based on the subjects' perception after the 20-min trials and measuring the vertical ground reaction force under the anterior wheel as well as the length of the center of pressure (COP) trajectory on the saddle. Results showed that the vertical force and the average value of mean pressure on the saddle significantly decreased during the 20-min period of testing for BAS and END. Mean peak pressure on the corresponding perineal cyclist area significantly increased only for BAS during the 20-min period. Interestingly objective comfort indexes measured did not match cyclists subjective comfort evaluation. The lower capacity of BAS to reduce the peak pressure on the corresponding perineal area after 20 min of testing, together with its positive comfort evaluation, suggest that a balance between protection and perceived comfort should be taken into account in the choice of the pad. Hence, the quantitative approach of objective comfort indexes introduced in this study could be helpful for manufacturers in the development of their protective pads.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4603024 | PMC |
http://dx.doi.org/10.1097/MD.0000000000001186 | DOI Listing |
ACS Nano
January 2025
School of Engineering, RMIT University, 124 La Trobe Street, Melbourne, Victoria 3001, Australia.
Modern-day applications demand onboard electricity generation that can be achieved using piezoelectric phenomena. Reducing the dimensionality of materials is a pathway to enhancing the piezoelectric properties. Transition-metal dichalcogenides have been shown to exhibit high piezoelectricity.
View Article and Find Full Text PDFCornea
January 2025
Department of Ophthalmology, Rothschild Foundation, Paris, France; and.
Purpose: The purpose of this study was to investigate the effect of hypoxia and hypobaric conditions on refraction and central corneal thickness on healthy corneas during an ascent without oxygen supplementation above 7000 m (23 000 ft).
Methods: Twelve multinational mountaineers were included in a prospective observational cohort study during an expedition to the Korzhenevskoi Peak (7105 m). The two patients excluded from the study had a history with keratoconus or were current wearers of rigid contact lenses.
Int J Exerc Sci
December 2024
Rehabilitation and Modulation of Pain (RAMP) Lab, Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, USA.
This study assessed the effect of an eight-minute cycling intervention using varying intensities on exercise-induced hypoalgesia (EIH). The main objective of this study was to examine the effect of varying intensities on pressure pain threshold (PPT) and heat pain threshold (HPT) at the thigh and forearm, tested pre- and post-cycling intervention. Healthy male participants ( = 16) performed a graded exercise test on a cycle ergometer to establish their peak power output (PPO).
View Article and Find Full Text PDFJ Soc Cardiovasc Angiogr Interv
December 2024
Imperial College London, United Kingdom.
Background: The mechanistic association between the hydraulic forces generated during contrast injection and the risk of coronary injury is poorly understood. In this study, we sought to evaluate whether contrast injections increase intracoronary pressures beyond resting levels and estimate the risk of hydraulic propagation of coronary dissections.
Methods: This is a prospective, single-arm, multicenter study that included patients with nonculprit, non-flow-limiting coronaries.
Curr Med Imaging
January 2025
Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Purpose: This study aimed to assess the hemodynamic changes in the vena cava and predict the likelihood of Cardiac Remodeling (CR) and Myocardial Fibrosis (MF) in athletes utilizing four-dimensional (4D) parameters.
Materials And Methods: A total of 108 athletes and 29 healthy sedentary controls were prospectively recruited and underwent Cardiac Magnetic Resonance (CMR) scanning. The 4D flow parameters, including both general and advanced parameters of four planes for the Superior Vena Cava (SVC) and Inferior Vena Cava (IVC) (sheets 1-4), were measured and compared between the different groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!