C-arm computed tomography (CT) is a new and innovative imaging technique. In combination with two-dimensional fluoroscopic or radiographic imaging, information provided by three-dimensional C-arm real time imaging can be valuable for therapy planning, guidance and outcome assessment in dental implant placement. This paper reports a case of two dental implant placement using Artis zee C-arm CT system first time in field of implantology.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4502030 | PMC |
http://dx.doi.org/10.1007/s13191-014-0366-y | DOI Listing |
J Stomatol Oral Maxillofac Surg
January 2025
Department of Prosthodontics and Gerostomatology, Poznan University of Medical Sciences, 60-792 Poznan, Poland.
Background: Tooth agenesis, particularly the absence of upper lateral incisors, presents substantial challenges for clinicians due to the associated bone atrophy, which limits the use of traditional implant solutions. Current options, such as endosseous implants combined with guided bone regeneration (GBR), often fail due to insufficient osseointegration in atrophic bone. This study aims to evaluate the effectiveness of custom-made, additively manufactured subperiosteal implants in addressing these challenges METHODS: This retrospective study assessed 16 custom-made subperiosteal implants used in 12 patients (10 females, 2 males; mean age 25 ± 2.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
DWI─Leibniz Institute for Interactive Materials e.V., Forckenbeckstraße 50, Aachen 52074, Germany.
The global dental implant market is projected to reach $9.5 billion by 2032, growing at a 6.5% compound annual growth rate due to the rising prevalence of dental diseases.
View Article and Find Full Text PDFClin Oral Implants Res
January 2025
Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one-piece zirconia implants fabricated from 3Y-TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three-unit fixed dental prostheses (FDP) after five years in function.
Materials And Methods: Twenty-seven patients received a total of 54 implants in a one-stage surgery with immediate provisionalization.
Objective: This study aims to evaluate the clinical efficacy of electro-pneumatic intracorporeal lithotripsy for the treatment of salivary gland stones.
Study Design: A prospective cohort study of patients diagnosed with obstructive salivary gland syndrome, where basket-assisted sialendoscopy alone failed to remove the calculi.
Setting: This study was conducted at the "Queen Maria" Military Hospital in Brașov, Romania, and a private practice, between February 2023 and May 2024.
Pak J Med Sci
January 2025
Sasankoti Mohan Ravi Prakash, DMD, MDS, BDS Dentist and Independent Researcher, Hope Health Inc, 360 N Irby St. Florence, South Carolina, USA 29501.
Background & Objective: Currently, there are many implants in clinical use, making it hard to choose the right one for the patient. The success rate of an implant depends on its diameter, length, and direction of insertion in bone. In implant dentistry, Finite Element Analysis (FEA) simulates intraoral conditions in vitro and analyzes the effects of implant material, diameter, size, and other components related to oral structure on the implant and peri-implant tissues.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!