Effect of lens care system on silicone hydrogel contact lens wettability.

Cont Lens Anterior Eye

Alcon Research, Ltd., Fort Worth, TX, USA.

Published: December 2015

Purpose: The purpose was to compare the effect of the repeated usage of two care systems (one hydrogen peroxide cleaning and disinfecting system and one polyaminopropyl biguanide (PHMB) containing multi-purpose system) with silicone hydrogel contact lenses worn for three months on a daily wear modality. A specific aspect of interest was of the effect of the care systems on contact lens wettability.

Methods: Seventy-four symptomatic contact lens wearers, habitually wearing either ACUVUE(®) OASYS(®) (n=37) or PureVision™ (n=37), constituted the study population. The study was a two-arm prospective, investigator-masked, bilateral study of three-month duration to evaluate the effects of CLEAR CARE(®) compared with renu(®) fresh™. The subjects were randomized to one of the two lens care systems. Contact lens wettability and surface cleanliness were assessed with the Tearscope and reported in terms of pre-lens non-invasive break-up time (PL-NIBUT) and visible deposits. Baseline assessments at enrollment were with the subjects' own contact lenses worn for at least 6h when using their habitual PHMB-preserved care system and at the dispensing visit with new contact lenses. At the follow-up visits, the contact lenses were worn for at least 6h, and were at least 11 days old for ACUVUE(®) OASYS(®) and 25 days old for PureVision™.

Results: The results obtained showed that: (i) with CLEAR CARE(®), a significant improvement in contact lens wettability was recorded compared with the habitual care system at the three-month follow-up visit (mean median PL-NIBUT 5.8 vs. 4.0 s, p<0.001). Further, with this same lens care system a significant increase in wettability was observed at the three-month follow-up visit compared with dispensing (mean median PL-NIBUT 5.8 vs. 4.5s, p=0.022). (ii) Whereas no difference in contact lens wettability was observed at dispensing between the two lens care groups (mean PL-NIBUT: 4.5 vs. 4.2s, p=0.518), a significantly more stable pre-lens tear film was observed with CLEAR CARE(®) than with renu(®) fresh™ at both the two-month (mean PL-NIBUT: 4.6 vs. 3.7s, p=0.005) and three-month (mean PL-NIBUT: 5.8 vs. 4.2 s, p=0.028) visits. iii. With renu(®) fresh™, no significant differences were observed at the end of three months of use compared with either the habitual care system or the new contact lens solution (mean PL-NIBUT: 3M 4.2 vs. Disp 4.2 s (p=0.420) vs. enrolment habitual care solution 5.1s (p=0.734)). iv. With CLEAR CARE(®) significant increases in the incidence of surfaces free of both mucus (3 month 95%. vs. habitual solution 82% enrolment; p=0.005) and lipid (3 month 87% vs. habitual solution 72% enrolment; p=0.009) were observed.

Conclusion: Significantly better contact lens wettability and surface cleanliness were achieved for ACUVUE(®) OASYS(®) and PureVision™ with CLEAR CARE(®) than with renu(®) fresh™ at the end of three months of use.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2015.06.007DOI Listing

Publication Analysis

Top Keywords

contact lens
20
contact lenses
16
care system
12
lens wettability
12
care systems
12
lenses worn
12
contact
9
lens care
8
system silicone
8
silicone hydrogel
8

Similar Publications

A woman in her 50s underwent simple limbal epithelial transplantation (SLET) in the left eye for chemical injury with total limbal stem cell deficiency. A seroma, a hitherto unreported complication of the procedure was noted on the 10th postoperative day. It was associated with an accumulation of inflammatory cells and exudates in the inferior part of the amniotic membrane resembling a hypopyon.

View Article and Find Full Text PDF

Purpose: To determine the countrywide prevalence of dry eye disease (DED) at the population level in Spain, and associated risks.

Methods: This was a cross-sectional study based on a telephone survey conducted in 2022. Participants from the general population were selected by sex, age, region, and population of residence to ensure the representativeness of the Spanish population.

View Article and Find Full Text PDF

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Perovskite-Based Smart Eyeglasses as Noncontact Human-Computer Interaction.

Adv Mater

January 2025

Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.

More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!