[Fiber bronchoscopy as an aid in placing and monitoring double lumen tubes in thoracic anesthesia].

Anasth Intensivther Notfallmed

Abt. für Anästhesie des Zentrums für Pneumologie und Thoraxchirurgie, Hamburg.

Published: December 1989

100 thoracic surgery patients were intubated by means of a left-hand Broncho-Cath PVC Double-Lumen Tube (DLT) and 10 further patients with a right-hand tube. In 76 of the 100 left-hand DLT's safe conventional placement of the tube was successful, oriented exclusively by auscultation findings and positive pressure respiration. However, fibre-optic control showed that only 44 of these tubes were correctly positioned (57.1%). 25 DLT's were too high and 24 too low, whereas the right main bronchus had been intubated in 6 cases. 1 DLT was endoscopically correctly placed although the positioning of the tube had been considered unsatisfactory during conventional examination. Only 2 right-hand DLT's fulfilled the conventional and endoscopic criteria for correct placement of the tube. All malpositionings could be corrected via fibre optics. Recurrent tube dislocations occurred both after lateral repositioning of the patients (so that they were now lying sideways) (27.3% of all patients) and intraoperatively (24.6% of all patients). Besides, intraoperative obstructions of the tube/bronchus lumen due to blood/coagulates (49.1% of the patients) and/or secretion (46.4% of the patients) could be demonstrated and eliminated by endoscopy. Fibre bronchoscopy proved to be a decisive help to reduce the possibilities of complications associated with the use of the Broncho-Cath PVC-DLT in thoracic surgery.

Download full-text PDF

Source

Publication Analysis

Top Keywords

thoracic surgery
8
placement tube
8
patients
7
tube
6
[fiber bronchoscopy
4
bronchoscopy aid
4
aid placing
4
placing monitoring
4
monitoring double
4
double lumen
4

Similar Publications

Objectives: This study aimed to comprehensively investigate the molecular landscape of gastric cancer (GC) by integrating various bioinformatics tools and experimental validations.

Methodology: GSE79973 dataset, limma package, STRING, UALCAN, GEPIA, OncoDB, cBioPortal, DAVID, TISIDB, Gene Set Cancer Analysis (GSCA), tissue samples, RT-qPCR, and cell proliferation assay were employed in this study.

Results: Analysis of the GSE79973 dataset identified 300 differentially expressed genes (DEGs), from which COL1A1, COL1A2, CHN1, and FN1 emerged as pivotal hub genes using protein-protein interaction network analysis.

View Article and Find Full Text PDF

Pneumocephalus and Pneumorrhachis Following Titanium Rib Implant: A Case Report and Literature Review.

Curr Med Imaging

January 2025

Consultant in Emergency Medicine, WIC Clinic, Primary Health Care Corporation, Doha, Qatar.

Introduction: Pneumocephalus and pneumorrhachis are rare postoperative complications, commonly occurring within a few days to months after spinal surgery. They are very rarely reported after thoracic surgeries. This case highlights a unique presentation in the emergency department involving headache and vomiting caused by late complications following thoracic surgery with a titanium rib implant.

View Article and Find Full Text PDF

Hybrid Arch Aneurysm Repair With Ascending Aortic Wrap and TEVAR.

J Endovasc Ther

January 2025

Aortic Center, Hôpital Marie-Lannelongue, Groupe Hospitalier Paris Saint Joseph, Université Paris-Saclay, INSERM UMR_S 999, Le Plessis Robinson, France.

Introduction: Management of patients with large aortic arch aneurysms who are considered high risk for frozen elephant trunk technique have been challenging, especially when they have a dilated ascending aorta (AA) that precludes total endovascular branched repair (arch BEVAR). A viable option in our armamentarium is wrapping of the AA (AW), and zone 0 Ishimaru TEVAR.

Methods: Retrospective analysis of our aortic database from 2013 to 2024 to select high-risk patients with aortic arch aneurysm that had an AW and TEVAR.

View Article and Find Full Text PDF

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!