A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ionic conductivity of peritoneal dialysate: a new, easy and fast method of assessing peritoneal membrane function in patients undergoing peritoneal dialysis. | LitMetric

Background: Peritoneal membrane function can be assessed using the peritoneal equilibration test (PET) and similar tests, but these are almost always complicated to use, require a considerable amount of working time and their results cannot always be easily interpreted. Ionic conductivity is a measure of the ability of an electrolyte solution to conduct electricity. We tested the hypothesis that the ionic conductivity of peritoneal dialysate can be used to evaluate peritoneal membrane function in peritoneal dialysis patients.

Methods: We measured the ionic conductivity and classic biochemical parameters of peritoneal dialysate in 69 patients during a modified PET and compared their ability to evaluate peritoneal membrane function and to diagnose ultrafiltration failure (UFF).

Results: Ionic conductivity was correlated well with classical parameters of peritoneal transport as glucose reabsorption of glucose (D/D0: r(2) = 0.62, P < 0.0001) and creatinine transport (D/PCreat: r(2) = 0.72, P < 0.0001). Twelve patients (17%) experienced UFF and, in them, the ionic conductivity area under the receiver-operating characteristic curve was 0.91 (95% confidence interval: 0.81-0.96) with sensitivity of 1.00 and specificity of 0.84 at a cut-off value of 12.75 mS/cm.

Conclusions: These findings indicate that the ionic conductivity of peritoneal dialysate can be used as a new screening tool to evaluate peritoneal membrane function.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ndt/gfv275DOI Listing

Publication Analysis

Top Keywords

ionic conductivity
28
peritoneal membrane
20
membrane function
20
peritoneal dialysate
16
peritoneal
13
conductivity peritoneal
12
evaluate peritoneal
12
peritoneal dialysis
8
parameters peritoneal
8
ionic
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!