MagicFinger: 3D Magnetic Fingerprints for Indoor Location.

Sensors (Basel)

Department of Information and Communications Engineering, University of Murcia, 30100 Murcia, Spain.

Published: July 2015

Given the indispensable role of mobile phones in everyday life, phone-centric sensing systems are ideal candidates for ubiquitous observation purposes. This paper presents a novel approach for mobile phone-centric observation applied to indoor location. The approach involves a location fingerprinting methodology that takes advantage of the presence of magnetic field anomalies inside buildings. Unlike existing work on the subject, which uses the intensity of magnetic field for fingerprinting, our approach uses all three components of the measured magnetic field vectors to improve accuracy. By using adequate soft computing techniques, it is possible to adequately balance the constraints of common solutions. The resulting system does not rely on any infrastructure devices and therefore is easy to manage and deploy. The proposed system consists of two phases: the offline phase and the online phase. In the offline phase, magnetic field measurements are taken throughout the building, and 3D maps are generated. Then, during the online phase, the user's location is estimated through the best estimator for each zone of the building. Experimental evaluations carried out in two different buildings confirm the satisfactory performance of indoor location based on magnetic field vectors. These evaluations provided an error of (11.34 m, 4.78 m) in the (x; y) components of the estimated positions in the first building where the experiments were carried out, with a standard deviation of (3.41 m, 4.68 m); and in the second building, an error of (4 m, 2.98 m) with a deviation of (2.64 m, 2.33 m).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541928PMC
http://dx.doi.org/10.3390/s150717168DOI Listing

Publication Analysis

Top Keywords

magnetic field
20
indoor location
12
field vectors
8
offline phase
8
online phase
8
location
5
magnetic
5
field
5
magicfinger magnetic
4
magnetic fingerprints
4

Similar Publications

Advanced cardiac imaging modalities have revolutionized the field of cardiovascular medicine, offering invaluable tools for both diagnosis and the management of a wide spectrum of cardiovascular diseases. These imaging methods, including echocardiography, cardiac computed tomography (CT), computed tomography angiography (CTA), cardiac magnetic resonance imaging (MRI), nuclear imaging, and fluoroscopy, offer various approaches to evaluate both the structure and function of the heart. This article provides an overview of imaging modalities for primary care physicians, highlighting their types, advantages, limitations and clinical uses.

View Article and Find Full Text PDF

Intrinsically disordered proteins and protein regions are central to many biological processes but difficult to characterize at atomic resolution. Nuclear magnetic resonance is particularly well-suited for providing structural and dynamical information on intrinsically disordered proteins, but existing NMR methodologies need to be constantly refined to provide greater sensitivity and resolution, particularly to capitalise on the potential of high magnetic fields to investigate large proteins. In this paper, we describe how N-detected 2D NMR experiments can be optimised for better performance.

View Article and Find Full Text PDF

Background: Splenic stiffness is a potential imaging marker of portal hypertension. Normative spleen stiffness values are needed to define diagnostic thresholds.

Objective: To report stiffness measurements of the spleen in healthy children undergoing liver magnetic resonance (MR) elastography across MRI vendors and field strengths.

View Article and Find Full Text PDF

Spin Hall nano-oscillators convert DC to magnetic auto-oscillations in the microwave regime. Current research on these devices is dedicated to creating next-generation energy-efficient hardware for communication technologies. Despite intensive research on magnetic auto-oscillations within the past decade, the nanoscale mapping of those dynamics remained a challenge.

View Article and Find Full Text PDF

Objectives: Evaluating the impact of an AI-based automated cardiac MRI (CMR) planning software on procedure errors and scan times compared to manual planning alone.

Material And Methods: Consecutive patients undergoing non-stress CMR were prospectively enrolled at a single center (August 2023-February 2024) and randomized into manual, or automated scan execution using prototype software. Patients with pacemakers, targeted indications, or inability to consent were excluded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!