Unlabelled: The aim was to analyze conventional planar scintigraphy and SPECT/CT in patients clinically suspicious for chylothorax or chylous ascites. Lymphoscintigraphy was performed for two reasons: first, to help diagnose chylothorax or -abdomen, by demonstrating diffuse uptake in fluid accumulations, and then secondly, to detect the site of leakage to test the prediction that additional use of SPECT/CT-technique improves upon the diagnostic value of planar lymphoscintigraphy in the baseline detection of thoraco-abdominal lymphatic disorders.

Patients, Material, Methods: From 7/2008-7/2014 a total of 24 consecutive patients (8 woman, 16 men; age, range 31-79 years) presenting with clinical symptoms suspicious for chylothorax and/or chylous ascites were examined by planar lymphoscintigraphy (n = 26) and additional tomographic SPECT/CT- (n = 22) or SPECT-technique (n = 2).

Results: Chylothorax could be scintigraphically confirmed in n = 9, chylous ascites in n = 5 scintigraphies, and excluded in n = 10 patients. In all planar scintigraphy findings of pathological lymph drainage regions (n = 14), SPECT/CT delivered additional relevant information, notably the anatomic localization of the lymphatic leakage. For the baseline detection of thoraco-abdominal lymphatic transport disorders, lymphoscintigraphy showed sensitivity of 88%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 80%.

Conclusions: Our findings show that due to the particular advantages presented by tomographic separation of overlapping sources, SPECT/CT specifies better the anatomical sites, improving the localization of lymphatic leakage in aid of planning surgical re-interventions.

Download full-text PDF

Source
http://dx.doi.org/10.3413/Nukmed-0723-15-02DOI Listing

Publication Analysis

Top Keywords

chylous ascites
16
planar scintigraphy
12
chylothorax chylous
8
suspicious chylothorax
8
planar lymphoscintigraphy
8
baseline detection
8
detection thoraco-abdominal
8
thoraco-abdominal lymphatic
8
localization lymphatic
8
lymphatic leakage
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!