Background: Titanium mesh has been employed in neurosurgery, plastic surgery, and maxillofacial surgery as a bone replacement in diverse conditions. We first reported on its use as a substitute for osteocartilaginous nasal structure with satisfactory functional and aesthetic results in 2009.

Objectives: To assess the utility and tolerance of titanium mesh as a substitute of the osteocartilaginous portion of the nose.

Materials And Methods: Eleven patients were identified who had a nasal reconstruction with titanium mesh. We retrospectively searched for infection, extrusion, nasal valve collapse, second surgery, and patient satisfaction in the patients' records. All patients presented with various types of non-melanoma skin cancer in the nasal pyramid. In the reconstruction of full-thickness nasal defects, local flaps were used, employing titanium mesh as a support structure.

Results: No mesh extrusions, infections, or collapse of the nasal valve were noted in patients with a mean follow-up of five years. Only one patient needed a second surgery to debulk the flap. Patient satisfaction achieved a mean score of 7.5 out of 9 in 10 patients.

Conclusions: As cartilage grafts need a second surgical site, with consequent morbidity, the use of titanium mesh proves useful and safe in the reconstruction of nasal full-thickness defects. The results of our series of patients demonstrate the suitability of this material in the repair of nasal osteochondral defects, as well as its low rate of complications.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ijd.12971DOI Listing

Publication Analysis

Top Keywords

titanium mesh
24
nasal
9
nasal pyramid
8
substitute osteocartilaginous
8
nasal valve
8
second surgery
8
patient satisfaction
8
titanium
6
mesh
6
surgery
5

Similar Publications

Alveolar ridge resorption following tooth loss poses a significant challenge for successful dental implant placement. In cases of severe atrophy, bone augmentation is required to restore sufficient bone volume. This technical note outlines a detailed, stepwise surgical protocol for horizontal and vertical alveolar ridge augmentation using customized titanium mesh.

View Article and Find Full Text PDF

Purpose: There are no universally established guidelines for material selection in orbital wall fracture reconstruction. With an increasing preference for permanent implants, this study aimed to compare the long-term clinical outcomes of three different non-resorbable materials in reconstructing isolated orbital floor fractures.

Design: A retrospective, interventional comparative study.

View Article and Find Full Text PDF

Metallic biomaterials are extensively used in orthopedics and dentistry, either as implants or coatings. In both cases, metal ions come into contact with surrounding tissues causing a particular cell response. Here, we present a biofabricated tissue model, consisting of a hydrogel reinforced with a melt electrowritten mesh, to study the effects of bound and released metal ions on surrounding cells embedded in a hydrogel matrix.

View Article and Find Full Text PDF

Background: Posterior vault distraction osteogenesis (PVDO) is an effective treatment for multisuture and syndromic craniosynostosis. It remains unclear how well the calvarium ossifies after PVDO, especially in older patients when they have plateaued in their cranial growth phase. The purpose of this study is to report outcomes associated with PVDO across a wide range of ages at our institution.

View Article and Find Full Text PDF

Evaluation of sticky bone in guided bone regeneration in the aesthetic area of the anterior teeth: a retrospective study.

Int J Oral Maxillofac Surg

January 2025

Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:

The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!