Background: Previous studies have shown that low blood pressure is associated with increased mortality and heart failure (HF) in patients with left ventricular dysfunction. Cardiac resynchronization therapy (CRT) was shown to increase systolic blood pressure (SBP). Therefore, we hypothesized that treatment with CRT would provide incremental benefit in patients with lower SBP values.
Methods And Results: The independent contribution of SBP to outcome was analyzed in 1267 patients with left bundle brunch block enrolled in Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). SBP was assessed as continuous measures and further categorized into approximate quintiles. The risk of long-term HF or death and CRT with defibrillator versus implantable cardioverter defibrillator benefit was assessed in multivariate Cox proportional hazards regression models. Multivariate analysis showed that in the implantable cardioverter defibrillator arm, each 10-mm Hg decrement of SBP was independently associated with a significant 21% (P<0.001) increased risk for HF or death, and patients with lower quintile SBP (<110 mm Hg) experienced a corresponding >2-fold risk-increase. CRT with defibrillator provided the greatest HF or mortality risk reduction in patients with SBP<110 mm Hg hazard ratio of 0.34, P<0.001, when compared with hazard ratio of 0.52, P<0.001, in those with 110>SBP≥136 mm Hg and hazard ratio of 0.94, P=0.808, with SBP>136 mm Hg (P for trend=0.001).
Conclusions: In patients with mild HF, prolonged QRS, and left bundle brunch block, low SBP is related to higher risk of mortality or HF with implantable cardioverter defibrillator therapy alone. Treatment with CRT is associated with incremental clinical benefits in patients with lower baseline SBP values.
Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCHEARTFAILURE.115.002208 | DOI Listing |
Eur Heart J Case Rep
January 2025
Department of Cardiology, Yokohama City University Hospital, 3-9 Fukuura, Kanazawa-Ku, Yokohama city, Kanagawa 236-0004, Japan.
Background: Coronary sinus (CS) lead placement in persistent left superior vena cava (PLSVC) cases is challenging because of the poor backup force of the guiding catheter within the enlarged CS. Active fixation Quadripolar leads (Attain Stability™ Quad 4798, Medtronic) can expand choice to CS branches with limited access; however, no cases of anchoring to the main body of the CS have been published to date.
Case Summary: We describe a case of cardiac resynchronization therapy pacemaker upgrade in a 79-year-old female who developed pacing-induced cardiomyopathy after pacemaker implantation via the right superior vena cava (SVC) for atrioventricular block eight years ago wherein PLSVC was revealed during the procedure.
Heart Rhythm
January 2025
Geisinger Heart Institute, Geisinger Wyoming Valley Medical Center, MC 36-10, 1000 E Mountain Blvd, Wilkes-Barre, PA 18711.
Micromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
Nucl Med Commun
January 2025
Department of Cardiac and Vascular Diseases, St.John Paul II Hospital, Jagiellonian University Medical College, Krakow, Poland.
Objectives: Cardiac resynchronization therapy (CRT) is an intervention for heart failure patients with reduced ejection fraction who exhibit specific electrocardiographic indicators of electrical dyssynchrony. However, electrical dyssynchrony does not universally correspond to left ventricular mechanical dyssynchrony (LVMD). Gated single-photon emission computed tomography (SPECT) myocardial perfusion allows for the assessment of LVMD, yet its role in the CRT selection process remains debated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!