Evaluation of transcutaneous and end-tidal carbon dioxide levels during inhalation sedation in volunteers.

J Clin Monit Comput

Division of Dental Anesthesiology, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, 1-3-27 Chuo-dori, Morioka, Iwate, 020-8505, Japan.

Published: August 2016

Measurement of end-tidal carbon dioxide (PETCO2) is useful because of its noninvasiveness, continuity, and response time when sudden changes in ventilation occur during inhalation sedation. We compared the accuracy of PETCO2 using a nasal mask and nasal cannula with the accuracy of transcutaneous carbon dioxide (TC-CO2) and determined which method is more useful during inhalation sedation in volunteers. We used a modified nasal mask (MNM) and modified nasal cannula (MNC) for measurement of PETCO2. The capnometer measured PETCO2 in the gas expired from the nasal cavity by means of two devices. The volunteers received supplemental O2 by means of each device at a flow rate of 6 L/min. After the volunteers lay quietly for 5 min with a supply of 100 % O2, they received supplemental N2O by means of each device at concentrations of 10, 20, and 25 % for 5 min and 30 % for 25 min. The correlation coefficient was poorer in the MNM than in the MNC, and the mean difference between TC-CO2 and PETCO2 in the MNM was greater than that in the MNC. The difference between the TC-CO2 and PETCO2 ranged from 3 to 6 mmHg in the MNM and from 2 to 5 mmHg in the MNC. The difference between two variables against the TC-CO2 and the CO2 waveforms obtained by means of the two devices were within the clinically acceptable range. Our two devices can provide continuous monitoring of PETCO2 with a supply of N2O/O2 in patients undergoing inhalation sedation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-015-9734-3DOI Listing

Publication Analysis

Top Keywords

inhalation sedation
16
carbon dioxide
12
mnc difference
12
end-tidal carbon
8
sedation volunteers
8
nasal mask
8
nasal cannula
8
modified nasal
8
received supplemental
8
difference tc-co2
8

Similar Publications

Introduction This report explores patient satisfaction in a dental sedation service in primary care for paediatric patients. The study explores different behavioural management techniques and additional supportive aids as adjuncts to inhalation sedation to improve patient satisfaction. Aim and objective To determine patient satisfaction with pre-assessment, treatment and aftercare in inhalation sedation services in primary care.

View Article and Find Full Text PDF

Treatment outcomes in adult patients experiencing dental anxiety: A comparative retrospective study.

Spec Care Dentist

January 2025

Department of Periodontology, Faculty of Dental Medicine, Hadassah Medical Center, Hebrew University of Jerusalem, Jerusalem, Israel.

Aims: To assess and compare the effectiveness of pharmacological and cognitive-behavioral modalities-behavioral methods (BM), nitrous oxide inhalation sedation (NOIS), and premedication with Diazepam-for alleviating anxiety during dental treatment, using completed treatment sessions and adverse outcomes as indicators.

Methods And Results: For 239 patients (515 dental records), 18-53 y/o, who underwent dental treatments under anxiety reduction measures, sessions under NOIS were categorized as "nitrous group" (456 sessions) versus premedication with Diazepam or behavioral strategies (control, 59 sessions). Outcomes were completed treatment sessions considering demographic and clinical parameters, and adverse outcomes during and between sessions.

View Article and Find Full Text PDF

When a difficult airway is anticipated, awake tracheal intubation can be considered. Usually, low doses of sedatives are administered during this procedure for minimal sedation and anxiolysis, such as midazolam and remifentanil. The newly developed ultra-short-acting benzodiazepine remimazolam has a pharmacokinetic profile that is more suitable for titration during awake tracheal intubation than the long-acting midazolam.

View Article and Find Full Text PDF

Rationale: It is imperative to be cautious about the potential systemic allergic reaction caused by the combined use of Qing Kailing Injection (QKI) and clindamycin as it may be life-threatening.

Patient Concerns: A 48-year-old female with a history of hypertension was admitted to a private hospital with a fever and cough. She was diagnosed with lung infection and received QKI infusion, followed by clindamycin infusion.

View Article and Find Full Text PDF

Introduction: Hypoxaemia is a frequent complication associated with endoscopy conducted under intravenous sedation, highlighting the need for effective and practical interventions. This systematic review aims to evaluate the effectiveness of nasal mask oxygenation in reducing the incidence of hypoxaemia during endoscopy under intravenous sedation compared with the conventional oxygen supply.

Methods And Analysis: This study strictly adheres to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol guidelines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!