Purpose: Unpleasant acoustic noise is a drawback of almost every MRI scan. Instead of reducing acoustic noise to improve patient comfort, we propose a technique for mitigating the noise problem by producing musical sounds directly from the switching magnetic fields while simultaneously quantifying multiple important tissue properties.

Theory And Methods: MP3 music files were converted to arbitrary encoding gradients, which were then used with varying flip angles and repetition times in a two- and three-dimensional magnetic resonance fingerprinting (MRF) examination. This new acquisition method, named MRF-Music, was used to quantify T1 , T2 , and proton density maps simultaneously while providing pleasing sounds to the patients.

Results: MRF-Music scans improved patient comfort significantly during MRI examinations. The T1 and T2 values measured from phantom are in good agreement with those from the standard spin echo measurements. T1 and T2 values from the brain scan are also close to previously reported values.

Conclusions: MRF-Music sequence provides significant improvement in patient comfort compared with the MRF scan and other fast imaging techniques such as echo planar imaging and turbo spin echo scans. It is also a fast and accurate quantitative method that quantifies multiple relaxation parameters simultaneously. Magn Reson Med 75:2303-2314, 2016. © 2015 Wiley Periodicals, Inc.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4715797PMC
http://dx.doi.org/10.1002/mrm.25818DOI Listing

Publication Analysis

Top Keywords

patient comfort
16
magnetic resonance
8
resonance fingerprinting
8
improve patient
8
comfort mri
8
mri examinations
8
acoustic noise
8
spin echo
8
music-based magnetic
4
fingerprinting improve
4

Similar Publications

Introduction The Synaptive magnetic resonance imaging (MRI) system (Synaptive Medical, Toronto, Canada) is a midfield 0.5 T head-only scanner for imaging the head and neck in adults and pediatrics. The system received US FDA and Health Canada clearance for clinical use in 2020.

View Article and Find Full Text PDF

Background: Hospitalized children's patient safety incidents can have a significant long-term impact on their physical, psychological, cognitive, and social development. Family-centered care emphasizes engaging parents, and parental involvement is an effective way to ensure child safety. This study aims to identify the factors influencing parents of children with hospitalization experiences in their willingness to engage in patient safety.

View Article and Find Full Text PDF

Background: Biomarkers are essential tools for diagnosing diseases. Saliva, as a human fluid, effectively reflects the body's condition due to its rich composition. Analyzing saliva components allows for noninvasive, cost-effective, and time-efficient screening and diagnosis.

View Article and Find Full Text PDF

Purpose: To assess the efficacy, adherence, and tolerability of a new artificial tear based on arabinogalactan, hyaluronic acid, and trehalose in a population with dry eye disease (DED).

Methods: A retrospective, real-world, post-marketing study identified 96 adult patients (aged 18-80 years) with signs and symptoms of dry eye. These patients received fixed combination therapy with eye drops containing arabinogalactan, hyaluronic acid, and trehalose at various dosing schedules.

View Article and Find Full Text PDF

Background: Meibomian gland dysfunction (MGD) is a primary cause of evaporative dry eye disease (DED), which is often exacerbated by cataract surgery due to surgical trauma and inflammation. Thermal pulsation therapy (TPT) aims to enhance meibomian gland function and relieve dry eye symptoms. We conducted a systematic review and meta-analysis to evaluate the effectiveness of TPT in managing dry eye symptoms associated with cataract surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!