We fabricate carbon nanotube (CNT)-field effect transistors (FETs) with a changeable channel length and investigate the electron transport properties of single-walled, double-walled and triple-walled CNTs under uniaxial strain. In particular, we characterize the atomic structure of the same CNTs in the devices by transmission electron microscopy and correlate the strain-induced electronic property change to the chirality of the CNTs. Both the off-state resistance and on-state resistance are observed to change with the axial strain following an exponential function. The strain-induced band gap change obtained from the maximum resistance change in the transfer curve of the ambipolar FETs is quantitatively compared with the previous theoretical prediction and our DFTB calculation from the chirality of the CNTs. Although following the same trend, the experimentally obtained strain-induced band gap change is obviously larger (57%-170% larger) than the theoretical results for all the six CNTs, indicating that more work is needed to fully understand the strain-induced electronic property change of CNTs.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c5nr02947cDOI Listing

Publication Analysis

Top Keywords

strain-induced electronic
12
electronic property
12
property change
12
change chirality
8
chirality cnts
8
strain-induced band
8
band gap
8
gap change
8
change
7
cnts
6

Similar Publications

Conductive hydrogels have been showcased with substantial potential for soft wearable devices. However, the tedious preparation process and poor trade-off among overall properties, i.e.

View Article and Find Full Text PDF

Multiphysics modelling of the impact of skin deformation and strain on microneedle-based transdermal therapeutic delivery.

Acta Biomater

December 2024

UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Dublin 4, Ireland; School of Mechanical & Materials Engineering, University College Dublin, Belfield, Dublin 4, Ireland; UCD Charles Institute of Dermatology, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland; The Conway Institute of Biomolecular and Biomedical Research, University College Dublin, Dublin, Ireland. Electronic address:

Microneedle patches (MNs) hold enormous potential to facilitate the minimally-invasive delivery of drugs and vaccines transdermally. However, the micro-mechanics of skin deformation significantly influence the permeation of therapeutics through the skin. Previous studies often fail to appreciate the complexities in microneedle-skin mechanical interactions.

View Article and Find Full Text PDF

Compressive interatomic distance stimulates photocatalytic oxygen-oxygen coupling to hydrogen peroxide.

Sci Bull (Beijing)

December 2024

School of Chemistry and Chemical Engineering/Institute of Clean Energy and Materials/Guangzhou Key Laboratory for Clean Energy and Materials/Huangpu Hydrogen Innovation Center, Guangzhou University, Guangzhou 510006, China. Electronic address:

Photocatalytic hydrogen peroxide (HO) generation is largely subject to the sluggish conversion kinetics of the superoxide radical (O) intermediate, which has relatively low reactivity and requires high energy. Here, we present a lattice-strain strategy to accelerate the conversion of O to highly active singlet oxygen(O) by optimizing the distance between two adjacent active sites, thereby stimulating HO generation via low-barrier oxygen-oxygen coupling. As the initial demonstration, the defect-induced strain in ZnInS nanosheet optimizes the distance of two adjacent Zn sites from 3.

View Article and Find Full Text PDF

Many printed electronic applications require strain-independent electrical properties to ensure deformation-independent performance. Thus, developing printed, flexible devices using 2D and other nanomaterials will require an understanding of the effect of strain on the electrical properties of nano-networks. Here, novel AC electrical techniques are introduced to fully characterize the effect of strain on the resistance of high-mobility printed networks, fabricated from of electrochemically exfoliated MoS nanosheets.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigates the stability of uncemented hip implants during total hip arthroplasty (THA) by examining bone compaction and the contact area between bone and implant using μCT scans of cadaveric femur samples.
  • - Researchers quantified the surgical-induced bone compaction using parameters like displacement and strain, and assessed bone volume fraction changes, finding that bone deformity and increased contact area were achieved despite limited bone-implant contact.
  • - The results highlight key behaviors of bone-implant interactions, offering valuable data for pre-surgical planning and improving implant selection for better stability in uncemented THA procedures.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!