Background: Hemovigilance is an important aspect of transfusion medicine. However, the frequency of the adverse reactions often varies using different reporters. Recently, we have employed a new information technology (IT)-based in-hospital hemovigilance system. Here, we evaluated changes in practice after implementation of an IT-based reporting system.
Study Design And Methods: We compared the rate of frequency and details of blood transfusion-related adverse reactions 3 years before and after introduction of the IT-based reporting system. Contents and severity of the adverse reactions were reported in a paper-based reporting system, but input by selecting items in an IT-based reporting system. The details of adverse reactions are immediately sent to the blood transfusion unit online.
Results: After we introduced the IT-based reporting system, the reported rate of transfusion-related adverse reactions increased approximately 10-fold from 0.20% to 2.18% (p < 0.001), and frequencies of urticaria, pruritus, rash, fever (p < 0.001), hypertension (p = 0.001), tachycardia (p = 0.003), and nausea and vomiting (p = 0.010) increased significantly. Although there was no error report in the paper-based reporting, incorrect reports were observed in 90 cases (0.52%) in the IT-based reporting (p < 0.001).
Conclusion: The advantages of IT-based reporting were: 1) a significant increase in the frequency of adverse reaction reporting and 2) a significant decrease in underreporting, although the true frequency has yet to be clarified. The disadvantage of the IT-based reporting was an increased incidence of incorrect inputs, all of which was unnoticed by the reporters. Our results showed several important points in need of monitoring after introduction of an IT-based reporting system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/trf.13228 | DOI Listing |
Chem Soc Rev
January 2025
Department of Chemistry, Purdue University, West Lafayette, Indiana, 47906, USA.
The light-absorbing chemical components of atmospheric organic aerosols are commonly referred to as Brown Carbon (BrC), reflecting the characteristic yellowish to brown appearance of aerosol. BrC is a highly complex mixture of organic compounds with diverse compositions and variable optical properties of its individual chromophores. BrC significantly influences the radiative budget of the climate and contributes to adverse air pollution effects such as reduced visibility and the presence of inhalable pollutants and irritants.
View Article and Find Full Text PDFEur J Breast Health
January 2025
Department of General Surgery, Barking Havering and Redbridge University NHS Trust, London, England, United Kingdom.
We investigate the evidence for adverse effects of intraparenchymal and peritumoral application of isosulfan blue dye in sentinel lymph node (SLN) mapping in breast cancer patients. A meta-analysis on the adverse effects of intraparenchymal and peritumoral application of isosulfan application in SLN mapping was conducted using Medline and Embase databases up to 2023. Procedure-based adverse reactions were divided into three grades: Grade I (allergic skin reactions), Grade II (hypotension) and Grade III (requiring vasopressor support).
View Article and Find Full Text PDFUrogynecology (Phila)
January 2025
From the Division of Urogynecology and Reconstructive Pelvic Surgery, TriHealth, Cincinnati, OH.
Importance: This study is important as it challenges the effectiveness of silver-coated catheters in reducing urinary tract infections (UTIs) after pelvic floor surgery (PFS).
Objective: The aim of this study was to investigate the incidence of UTIs in patients using silver-coated silicone transurethral indwelling catheters (TICs) compared with standard silicone TICs among women with postoperative urinary retention following PFS.
Study Design: This was a double-blind, randomized controlled trial of women undergoing PFS between June 2022 and February 2024 with postoperative urinary retention.
Heparin-induced thrombocytopenia (HIT) is an adverse drug reaction with significant thromboembolic risk. Though there are models for use of non-heparin anticoagulants, heparin remains the preferred anticoagulant in many operative settings, especially cardiovascular surgery and percutaneous cardiac intervention. The natural history of HIT can be stereotyped into phases using HIT laboratory testing to guide clinical management and determine whether heparin re-exposure can be considered.
View Article and Find Full Text PDFTheranostics
January 2025
Department of Neurosurgery, Qilu Hospital, Cheeloo College of Medicine and Institute of Brain and Brain-Inspired Science, Shandong University, Shandong, China.
Endothelial-to-mesenchymal transition (EndMT) is a cellular reprogramming mechanism by which endothelial cells acquire a mesenchymal phenotype. Endothelial cell dysfunction is the initiating factor of atherosclerosis (AS). Increasing evidence suggests that EndMT contributes to the occurrence and progression of atherosclerotic lesions and plaque instability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!