Purpose: The insertion of tunneled central venous access catheters (CVCs) in infants can be challenging. The use of the ultrasound-guided (UG) approach to CVC placement has been reported in adults and children, but the technique is not well studied in infants.
Subjects And Methods: A retrospective review was performed of infants under 3.5 kg who underwent attempted UG CVC placement between August 2012 and November 2013. All infants underwent UG CVC placement using a standard 4.2-French or 3.0-French CVC system (Bard Access Systems, Inc., Salt Lake City, UT). The UG approach was performed on all infants with the M-Turbo(®) ultrasound system (SonoSite, Inc., Bothell, WA). The prepackaged 0.025-inch-diameter J wire within the set was used in all infants weighing greater than 2.5 kg. A 0.018-inch-diameter angled glidewire (Radiofocus(®) GLIDEWIRE(®); Boston Scientific Inc., Natick, MA) was used in infants less than 2.5 kg. Data collected included infant weight, vascular access site, diameter of cannulated vein (in mm), and complications.
Results: Twenty infants underwent 21 UG CVC placements (mean weight, 2.4 kg; range, 1.4-3.4 kg). Vascular CVC placement occurred at the following access sites: 16 infants underwent 17 placements via the right internal jugular vein, versus 3 infants via the left internal jugular vein. The average size of the target vessel was 4.0 mm (range, 3.5-5.0 mm). One infant had inadvertent removal of the UG CVC in the right internal jugular vein on postoperative Day 7. This infant returned to the operating room and underwent a successful UG CVC in the same right internal jugular vein. There were no other complications in the group.
Conclusions: The UG CVC approach is a safe and efficient approach to central venous access in infants as small as 1.4 kg. Our experience supports the use of a UG percutaneous technique as the initial approach in underweight infants who require central venous access.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/lap.2014.0308 | DOI Listing |
Invest Radiol
January 2025
From the Department of Radiology, Ulsan University Hospital, Ulsan, Republic of Korea (T.Y.L.); Department of Radiology, University of Ulsan College of Medicine, Seoul, Republic of Korea (T.Y.L.); Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea (J.H.Y., H.K., J.M.L.); Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea (J.H.Y., S.H.P., J.M.L.); Department of Radiology, Inje University Busan Paik Hospital, Busan, Republic of Korea (J.Y.P.); Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea (S.H.P.); Department of Radiology, Hanyang University College of Medicine, Seoul, Republic of Korea (C.L.); Division of Biostatistics, Medical Research Collaborating Center, Seoul National University Hospital, Seoul, Republic of Korea (Y.C.); and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea (J.M.L.).
Objective: The aim of this study was to intraindividually compare the conspicuity of focal liver lesions (FLLs) between low- and ultra-low-dose computed tomography (CT) with deep learning reconstruction (DLR) and standard-dose CT with model-based iterative reconstruction (MBIR) from a single CT using dual-split scan in patients with suspected liver metastasis via a noninferiority design.
Materials And Methods: This prospective study enrolled participants who met the eligibility criteria at 2 tertiary hospitals in South Korea from June 2022 to January 2023. The criteria included (a) being aged between 20 and 85 years and (b) having suspected or known liver metastases.
J Ren Care
March 2025
School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia.
Background: Globally, haemodialysis is the most frequent type of kidney replacement therapy and necessitates access to the bloodstream either through a native arteriovenous fistula, arteriovenous graft or central venous catheter. Vascular access complications are a major cause of morbidity and mortality in adults receiving haemodialysis, and effective vascular access self-management is required.
Objective: To examine the effectiveness of educational or behavioural interventions designed to improve self-management of long-term vascular access in adults receiving haemodialysis.
J Perioper Pract
January 2025
San Juan Veterans Affairs Medical Center, San Juan, Puerto Rico.
Case: An active healthy 68-year-old male sustained a bilateral quadriceps tendon rupture while running. He underwent a simultaneous bilateral quadriceps tendon repair in a dual-surgeon approach. The right quadriceps tendon was repaired with a tourniquet, while the left quadriceps tendon tear was repaired without one.
View Article and Find Full Text PDFCureus
December 2024
Anesthesiology and Critical Care, Faculty of Medicine, University of Banja Luka, Banja Luka, BIH.
Cervical plexus block (CPB), like other types of regional anesthesia, represents an alternative anesthetic technique in those cases where the performance of general anesthesia (GA) carries an increased risk both for the patient and the outcome of the operative treatment. It has traditionally been used for years in carotid surgery as an alternative to GA, especially due to the possibility of superior monitoring - the awake patient. However, its effectiveness has been proven in other types of neck surgery, primarily in thyroid surgery, neck dissections, tracheostomy, central venous catheter insertion, clavicle surgery, etc.
View Article and Find Full Text PDFIndian J Nephrol
July 2024
Department of Medicine, INHS Asvini, Mumbai, India.
Background: External jugular vein (EJV) is used to insert tunneled dialysis catheter (TDC) in patients with no AVF and exhausted right internal jugular veins (IJV). There is scarce data on TDC insertion in EJV by nephrologists with fluoroscopy guidance.
Materials And Methods: This was a prospective observational study that included hemodialysis patients with exhausted right IJV access who underwent EJV TDC insertion, and excluded occluded ipsilateral brachiocephalic vein or superior vena cava, EJV < 5 mm diameter, or patients with existing EJV TDC.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!