Study Design: A biomechanical study comparing arthroplasty with fusion using human cadaveric C2-T1 spines.
Objective: To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs.
Summary Of Background Data: Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration.
Methods: 11 specimens (C2-T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5-C6, 2-level TDR at C5-C6-C7, fusion at C5-C6 and TDR at C6-C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2-T1) matched the motion of the respective intact state (hybrid control).
Results: An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels.
Conclusion: Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BRS.0000000000001044 | DOI Listing |
Am J Sports Med
January 2025
Midwest Orthopaedics at Rush, Chicago, Illinois, USA.
Background: Elbow injuries are prevalent among professional baseball pitchers as nearly 25% undergo ulnar collateral ligament reconstruction. Pitch type, ball velocity, and spin rate have been previously hypothesized to influence elbow varus torque and subsequent risk of injury, but existing research is inconclusive.
Purpose: To examine elbow varus torque, cumulative torque, and loading rate within professional pitchers throwing fastball, curveball, change-up, and slider pitches, as well as to identify potential influences of ball spin on the elbow.
Am J Sports Med
January 2025
Rothman Orthopaedic Institute, Philadelphia, Pennsylvania, USA.
Background: Ruptures of the distal biceps tendon (DBT) can affect the range of motion and strength of the elbow, raising concerns for patients seeking to restore normal function and engage in their regular activities, particularly returning to previous levels of sport participation.
Purpose: To characterize and assess the rate and timing of return to sport (RTS) after DBT repair.
Study Design: Systematic review; Level of evidence, 4.
Rev Sci Instrum
January 2025
Shanxi Key Laboratory of Intelligent Detection Technology and Equipment, School of Information and Communication Engineering, North University of China, Taiyuan 030051, Shanxi, China.
Real-time moving target trajectory prediction is highly valuable in applications such as automatic driving, target tracking, and motion prediction. This paper examines the projection of three-dimensional random motion of an object in space onto a sensing plane as an illustrative example. Historical running trajectory data are used to train a reserve network.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Department of Chemistry, Michigan State University, East Lansing, MI 48824.
The natural vibrational frequencies of biological particles such as viruses and bacteria encode critical information about their mechanical and biological states as they interact with their local environment and undergo structural evolution. However, detecting and tracking these vibrations within a biological context at the single particle level has remained elusive. In this study, we track the vibrational motions of single, unlabeled virus particles under ambient conditions using ultrafast spectroscopy.
View Article and Find Full Text PDFImmun Inflamm Dis
January 2025
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Objective: This study aimed to evaluate the activity of extraocular muscles (EOMs) in patients with thyroid-associated ophthalmopathy (TAO) using turbo spin echo imaging. By analyzing tissue heterogeneity, apparent diffusion coefficient (ADC) histogram analysis offers enhanced insights into edema within the EOMs.
Methods: Eighty-eight patients with TAO were retrospectively evaluated and allocated into active (n = 24, clinical activity score [CAS] ≥ 3) and inactive (n = 64, CAS < 3) groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!