Accuracy of Patient-reported Adherence to Glaucoma Medications on a Visual Analog Scale Compared With Electronic Monitors.

Clin Ther

Division of Pharmaceutical Outcomes and Policy, UNC Eshelman School of Pharmacy, Chapel Hill, North Carolina; Cecil G. Sheps Center for Health Services Research, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina.

Published: September 2015

Purpose: Glaucoma medications can improve clinical outcomes when patients adhere to their medication regimen. Providers often ask patients with glaucoma to self-report their adherence, but the accuracy of self-reporting has received little scientific attention. The purpose of this article was to compare a self-reported medication adherence measure with adherence data collected from Medication Event Monitoring Systems (MEMS) electronic monitors. An additional goal was to identify which patient characteristics were associated with overreporting adherence on the self-reported measure.

Methods: English-speaking adult patients with glaucoma were recruited from 6 ophthalmology practices for this observational cohort study. Patients were interviewed after their initial visit and were given MEMS contains, which recorded adherence over a 60-day period. MEMS percent adherence measured the percentage of the prescribed number of doses taken. MEMS-measured timing adherence assessed the percent doses taken on time. Patients self-reported adherence to their glaucoma medications on a visual analog scale (VAS) ~60 days after the baseline visit. Bivariate analyses and logistic regressions were used to analyze the data. Self-reported medication adherence on the VAS was plotted against MEMS adherence to illustrate the discrepancy between self-reported and electronically monitored adherence.

Findings: The analyses included 240 patients who returned their MEMS containers and self-reported medication adherence at the 60-day follow-up visit. Compared with MEMS-measured percent adherence, 31% of patients (n = 75) overestimated their adherence on the VAS. Compared with MEMS-measured timing adherence, 74% (n = 177) of patients overestimated their adherence. For the MEMS-measured percent adherence, logistic regression revealed that patients who were newly prescribed glaucoma medications were significantly more likely to overreport adherence on the VAS (odds ratio, 3.07 [95% CI, 1.22-7.75]). For the MEMS-measured timing adherence, being male (χ(2) test, 6.78; P = 0.009) and being prescribed glaucoma medications dosed multiple times daily (χ(2) test, 4.02; P = 0.045) were significantly associated with patients overreporting adherence. However, only male sex remained a significant predictor of overreporting adherence in the logistic regression (odds ratio, 4.05 [95% CI, 1.73-9.47]).

Implications: Many patients with glaucoma, especially those newly diagnosed, overestimated their medication adherence. Because patients were likely to overreport the percent doses taken and timing adherence, providers may want to ask patients additional questions about when they take their glaucoma medications to potentially detect issues with taking these medications on time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4568126PMC
http://dx.doi.org/10.1016/j.clinthera.2015.06.008DOI Listing

Publication Analysis

Top Keywords

glaucoma medications
24
adherence
23
medication adherence
16
timing adherence
16
patients
13
patients glaucoma
12
self-reported medication
12
overreporting adherence
12
percent adherence
12
mems-measured timing
12

Similar Publications

Background: In recent years, with the rapid development of machine learning (ML), it has gained widespread attention from researchers in clinical practice. ML models appear to demonstrate promising accuracy in the diagnosis of complex diseases, as well as in predicting disease progression and prognosis. Some studies have applied it to ophthalmology, primarily for the diagnosis of pathologic myopia and high myopia-associated glaucoma, as well as for predicting the progression of high myopia.

View Article and Find Full Text PDF

Purpose: To employ a validated survey for evaluation of quality of life (QoL) outcomes and associated factors in a US cohort of adult patients with acquired anophthalmia wearing a prosthesis.

Methods: A retrospective cohort study was performed at a single, US academic institution of patients cared for between 2012 and 2021. The electronic medical record database was queried for adult patients with a history of evisceration or enucleation surgery and placement of an orbital implant.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of slow-coagulation transscleral cyclophotocoagulation (SC-TSCPC) in pseudoexfoliation glaucoma (PXG).

Methods: A single-center, retrospective non-comparative study including consecutive patients with medically uncontrolled PXG who underwent SC-TSCPC (1250-milliwatt power and 4-second duration). The primary outcome measure was surgical success (defined as intraocular pressure (IOP) between 6 - 21 mmHg with ≥20% reduction compared to baseline and no need for further glaucoma surgeries or development of vision-threatening complications).

View Article and Find Full Text PDF

Basic Science and Pathogenesis.

Alzheimers Dement

December 2024

Tohoku Medical Megabank Organization, Tohoku University, Sendai, Japan.

Background: Dementia is age-related with a significant genetic contribution, yet genome-wide association studies have not fully accounted for heritability. This discrepancy may in part be due to reliance on SNPs and small indels. Whole-genome sequencing (WGS) data in the Japanese population may reveal population-specific susceptibility loci for dementia.

View Article and Find Full Text PDF

Prcis: Preservative-free omidenepag isopropyl (OMDI) 0.002% ophthalmic solution and OMDI 0.002% ophthalmic solution preserved with benzalkonium chloride were bioequivalent in lowering intraocular pressure after 4 weeks' treatment in patients with primary open-angle glaucoma or ocular hypertension.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!