In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncv368 | DOI Listing |
Small Methods
December 2024
Institute of Translational Medicine, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
Colored contact lenses have gained popularity among young individuals owing to their ability to alter the appearance of the wearer's eyes. However, conventional lenses containing chemical dyes are susceptible to detachment of the pigment layer, which can lead to corneal damage. In this research, a novel cellulose-based structural color contact lens (SCCL) is presented that enhances aesthetic appeal via a cholesteric liquid crystal (CLC) layer.
View Article and Find Full Text PDFClin Ophthalmol
December 2024
Department of Ophthalmology, Visual and Anatomical Sciences, Kresge Eye Institute/Wayne State University School of Medicine, Detroit, MI, USA.
Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.
Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.
Cureus
November 2024
Ophthalmology, Moorfields Eye Hospital, London, GBR.
We report a case of spontaneous total iris avulsion that occurred during corneal wound hydration following an uneventful phacoemulsification procedure. An 86-year-old woman underwent cataract surgery on her right eye, during which a single-piece acrylic intraocular lens (Bausch and Lomb Akreos Adapt Advanced Optics, Bausch and Lomb Incorporated, Rochester, NY, USA) was implanted in the bag, and the viscoelastic material was removed. During corneal wound hydration, total iris avulsion was observed, with the iris prolapsing out of the anterior chamber through the main wound.
View Article and Find Full Text PDFEye Vis (Lond)
December 2024
Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, China.
Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes.
View Article and Find Full Text PDFOcul Surf
December 2024
AZURA Ophthalmics, Tel-Aviv, Israel.
Background: Contact lens discomfort (CLD) is a common problem for CL wearers, and patients with CLD often have changes in meibomian gland function and structure. In a Phase 2 trial AZR-MD-001 0.5% (AZR) ophthalmic ointment improved meibomian gland dysfunction (MGD) in non-lens wearers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!