Objective: To compare sensitivity and specificity of endovaginal versus external-array coil T2-W and T2-W + DWI for detecting and staging small cervical tumours.

Methods: Optimised endovaginal and external array coil MRI at 3.0-T was done prospectively in 48 consecutive patients with stage Ia/Ib1 cervical cancer. Sensitivity/specificity for detecting tumour and parametrial extension against histopathology for a reading radiologist were determined on coronal T2-W and T2W + DW images. An independent radiologist also scored T2-W images without and with addition of DWI for the external-array and endovaginal coils on separate occasions >2 weeks apart. Cohen's kappa assessed inter- and intra-observer agreement.

Results: Median tumour volume in 19/38 cases positive on subsequent histology was 1.75 cm(3). Sensitivity, specificity, PPV, NPV were: reading radiologist 91.3 %, 89.5 %, 91.3 %, 89.5 %, respectively; independent radiologist T2-W 82.6 %, 73.7 %, 79.1 %, 77.8 % for endovaginal, 73.9 %, 89.5 %, 89.5 %, 73.9 % for external-array coil. Adding DWI improved sensitivity and specificity of endovaginal imaging (78.2 %, 89.5 %); adding DWI to external-array imaging improved specificity (94.7 %) but reduced sensitivity (66.7 %). Inter- and intra-observer agreement on T2-W + DWI was good (kappa = 0.67 and 0.62, respectively).

Conclusion: Endovaginal coil T2-W MRI is more sensitive than external-array coil for detecting tumours <2 cm(3); adding DWI improves specificity of endovaginal imaging but reduces sensitivity of external-array imaging.

Key Points: • Endovaginal more accurate than external-array T2-W MRI for detecting small cervical cancers. • Addition of DWI improves sensitivity and specificity of endovaginal T2-W imaging. • Addition of DWI substantially reduces sensitivity of external-array T2-W imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4778155PMC
http://dx.doi.org/10.1007/s00330-015-3899-5DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
12
external-array coil
12
optimised endovaginal
8
endovaginal external
8
external array
8
array coil
8
stage ia/ib1
8
cervical cancer
8
specificity endovaginal
8
coil t2-w
8

Similar Publications

Purpose: Current technologies to define the zone of acute peripheral nerve injury intraoperatively are limited by surgical experience, time, cumbersome electrodiagnostic equipment, and interpreter reliability. In this pilot study, we evaluated a real-time, label-free optical technique for intraoperative nerve injury imaging. We hypothesize that fluorescence lifetime imaging (FLIm) will detect a difference between the time-resolved fluorescence signatures for acute crush injuries versus uninjured segments of peripheral nerves in sheep.

View Article and Find Full Text PDF

Heavy metal pollution is a major environmental and health problem due to the toxicity and persistence of metals such as lead, mercury, cadmium, and arsenic in water, soil, and air. Advances in sensor technology have significantly improved the detection and quantification of heavy metals, providing real-time monitoring and mitigation tools. This review explores recent developments in heavy metal detection, focusing on innovative uses of immobilized chromogenic reagents, nanomaterials, perovskites, and nanozymes.

View Article and Find Full Text PDF

Cervical cancer remains a major global health concern, with a specially alarming incidence in younger women. Traditional detection techniques such as the Pap smear and colposcopy often lack sensitivity and specificity and are highly dependent on the experience of the gynaecologist. In response, this study proposes the use of Hyperspectral Imaging, a pioneering technology that combines traditional imaging with spectroscopy to provide detailed spatial and spectral information.

View Article and Find Full Text PDF

Susceptibility map-weighted MRI can distinguish tremor-dominant Parkinson's disease from essential tremor.

Sci Rep

January 2025

Department of Neurology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.

Distinguishing between Parkinson's disease (PD) and essential tremor (ET) can be challenging sometimes. Although positron emission tomography can confirm PD diagnosis, its application is limited by high cost and exposure to radioactive isotopes. Patients with PD exhibit loss of the dorsal nigral hyperintensity on brain magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Background: Overexpression of tear matrix metalloproteinases-9 (MMP-9) on the ocular surface tissues has been reported to result in ocular surface damage. MMP-9 levels in tears have been listed as one of many tools for confirming dry eye disease (DED).

Objective: This investigation aimed to compare MMP-9 levels and ocular surface parameters in diabetic patients with and without DED.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!