Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We use measurements made onboard the National Science Foundation's C-130 research aircraft during the 2013 Nitrogen, Oxidants, Mercury, and Aerosol Distributions, Sources, and Sinks (NOMADSS) experiment to examine total Hg (THg) emission ratios (EmRs) for six coal-fired power plants (CFPPs) in the southeastern U.S. We compare observed enhancement ratios (ERs) with EmRs calculated using Hg emissions data from two inventories: the National Emissions Inventory (NEI) and the Toxics Release Inventory (TRI). For four CFPPs, our measured ERs are strongly correlated with EmRs based on the 2011 NEI (r(2) = 0.97), although the inventory data exhibit a -39% low bias. Our measurements agree best (to within ±32%) with the NEI Hg data when the latter were derived from on-site emissions measurements. Conversely, the NEI underestimates by approximately 1 order of magnitude the ERs we measured for one previously untested CFPP. Measured ERs are uncorrelated with values based on the 2013 TRI, which also tends to be biased low. Our results suggest that the Hg inventories can be improved by targeting CFPPs for which the NEI- and TRI-based EmRs have significant disagreements. We recommend that future versions of the Hg inventories should provide greater traceability and uncertainty estimates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.est.5b01755 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!