RETROSPECTIVE DETECTION OF INTERLEAVED SLICE ACQUISITION PARAMETERS FROM FMRI DATA.

Proc IEEE Int Symp Biomed Imaging

Department of Neurology, and Biomedical Engineering, Columbia University, New York, NY 10032. USA.

Published: January 2014

To minimize slice excitation leakage to adjacent slices, interleaved slice acquisition is nowadays performed regularly in fMRI scanners. In interleaved slice acquisition, the number of slices skipped between two consecutive slice acquisitions is often referred to as the 'interleave parameter'; the loss of this parameter can be catastrophic for the analysis of fMRI data. In this article we present a method to retrospectively detect the interleave parameter and the axis in which it is applied. Our method relies on the smoothness of the temporal-distance correlation function, which becomes disrupted along the axis on which interleaved slice acquisition is applied. We examined this method on simulated and real data in the presence of fMRI artifacts such as physiological noise, motion, etc. We also examined the reliability of this method in detecting different types of interleave parameters and demonstrated an accuracy of about 94% in more than 1000 real fMRI scans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4494742PMC
http://dx.doi.org/10.1109/ISBI.2014.6867803DOI Listing

Publication Analysis

Top Keywords

interleaved slice
16
slice acquisition
16
fmri data
8
slice
6
fmri
5
retrospective detection
4
interleaved
4
detection interleaved
4
acquisition
4
acquisition parameters
4

Similar Publications

Article Synopsis
  • The study aimed to enhance vessel visibility in MR imaging by adjusting k-space filling techniques and to assess the effectiveness of an AI approach for detecting brain metastases using a method called VISIBLE with compressed sensitivity encoding (CS).
  • Three variations of the VISIBLE sequence (Centric, Reversed Centric, and Startup Echo 30) were tested. While the Reversed Centric method produced fewer false positives, all three showed similar sensitivity and specificity for brain metastasis detection.
  • The findings indicated that modifying k-space filling improves vessel visibility and reduces false positives, while the AI model proved effective in autonomously detecting brain metastases in the MRI scans.
View Article and Find Full Text PDF

With the development of mobile communication, digital signatures with low latency, low area, and high security are in increasing demand. Elliptic curve cryptography (ECC) is widely used because of its security and lightweight. Elliptic curve scalar multiplication (ECSM) is the basic arithmetic in ECC.

View Article and Find Full Text PDF

Efficient abdominal coverage with T1-mapping methods currently available in the clinic is limited by the breath hold period (BHP) and the time needed for T1 recovery. This work develops a T1-mapping framework for efficient abdominal coverage based on rapid T1 recovery curve (T1RC) sampling, slice-selective inversion, optimized slice interleaving, and a convolutional neural network (CNN)-based T1 estimation. The effect of reducing the T1RC sampling was evaluated by comparing T1 estimates from T1RC ranging from 0.

View Article and Find Full Text PDF

In this work, echo-planar spectroscopic imaging (EPSI) with flyback readout gradient-echo train was implemented in a preclinical MR scanner. The aim of this study is to visualize and quantify the ghost spectral lines produced by two, three and four interleaved echo trains with different amplitudes of the readout gradients, and to investigate the feasibility of the flyback data acquisition in micro-imaging of small animals. Applied multi-slice EPSI sequence utilizes asymmetric gradient-echo train that combines the shortest possible rewind gradients with readout gradients.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to create a new MRI pulse sequence called PRIME, which improves diffusion MRI by adding an echo to obtain high-resolution images without increasing scan time.
  • The PRIME technique uses two echoes: one for detailed diffusion imaging and the second for generating accurate field maps or matching resolutions for efficient data acquisition.
  • Results showed that the PRIME sequence successfully achieved fast and clear diffusion imaging in healthy volunteers, allowing for high-quality images and detailed analysis without distortion.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!