Mechanical properties of a bioabsorbable nerve guide tube for long nerve defects.

Chir Main

Department of bioartificial organs, institute for frontier medical sciences, Kyoto university, Sakyo-ku, 606-8507 Kyoto, Japan.

Published: September 2015

The mechanical properties of nerve guide tubes must be taken into consideration when they are being developed. We previously reported the feasibility of using 50:50 tubes in a canine 40mm peroneal nerve defect model, where 50:50 represents the proportion of poly(L-lactic) acid (PLLA) and polyglycolic acid (PGA). The aim of the current study was to show that 50:50 tubes have suitable mechanical properties for repairing long nerve defects. Four types of nerve guide tubes made with PLLA to PGA fiber ratios of 100:0 (i.e. 100% PLLA) (100:0 tube), 50:50 (50:50 tube), 10:90 (10:90 tube), and 0:100 (0:100 tube) were designed and created using a tubular braiding machine. Their mechanical properties were examined in vitro (up to 16 weeks). In compression testing, 50:50 tubes had the highest normalized force value, followed in order by the 100:0, 10:90, and 0:100 tubes up to 8 weeks after immersion. From the point of view of biomechanics and bioresorbability, out of the 4 tube types tested, 50:50 tubes appeared to have the optimal mechanical properties for longer nerve defects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.main.2015.05.004DOI Listing

Publication Analysis

Top Keywords

mechanical properties
20
5050 tubes
16
nerve guide
12
nerve defects
12
long nerve
8
guide tubes
8
nerve
7
tubes
7
0
7
tube
6

Similar Publications

The cytoplasm exhibits viscoelastic properties, displaying both solid and liquid-like behavior, and can actively regulate its mechanical attributes. The cytoskeleton is a major regulator among the numerous factors influencing cytoplasmic mechanics. We explore the interdependence of various cytoskeletal filaments and the impact of their density on cytoplasmic viscoelasticity.

View Article and Find Full Text PDF

MXenes are a class of 2D transition metal carbides and nitrides (MXT) that have attracted significant interest owing to their remarkable potential in various fields. The unique combination of their excellent electromagnetic, optical, mechanical, and physical properties have extended their applications to the biological realm as well. In particular, their ultra-thin layered structure holds specific promise for diverse biomedical applications.

View Article and Find Full Text PDF

An Injectable Alginate Hydrogel Modified by Collagen and Fibronectin for Better Cellular Environment.

ACS Appl Bio Mater

January 2025

Division of Plastic Surgery, Department of Surgery, Yale School of Medicine, Yale University, 310 Cedar Street, New Haven, Connecticut 06510, United States.

Encapsulating fibroblasts in alginate hydrogels is a promising strategy to promote wound healing. However, improving the cell function within the alginate matrix remains a challenge. In this study, we engineer an injectable hydrogel through mixing alginate function with collagen and fibronectin, creating a better microenvironment for enhancing fibroblast function and cytokine secretion.

View Article and Find Full Text PDF

Background: Previous studies have suggested that changes in the composition of the extracellular matrix (ECM) play a significant role in the development of ligamentum flavum hypertrophy (LFH) and the histological differences between the ventral and dorsal layers of the hypertrophied ligamentum flavum. Although LFH is associated with increased fibrosis in the dorsal layer, comprehensive research exploring the characteristics of the ECM and its mechanical properties in both regions is limited. Furthermore, the distribution of fibrosis-associated myofibroblasts within LFH remains poorly understood.

View Article and Find Full Text PDF

Laser surface alloying of Fe, Si, and C on aluminium is demonstrated using a Q-switched Nd:YAG laser as the source of energy. The fundamental wavelength of the laser beam was 1064 nm with an output energy of 100 mJ and a pulse duration of 10 ns. The exposure was conducted in repetitive mode with a frequency rate of 1 Hz.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!