Automated working distance adjustment enables optical coherence tomography of the human larynx in awake patients.

J Med Imaging (Bellingham)

Laser Zentrum Hannover e.V. , Biomedical Optics Department, Hollerithallee 8, 30419 Hannover, Germany.

Published: April 2015

Optical coherence tomography (OCT) provides structural information of laryngeal tissue which is comparable to histopathological analysis of biopsies taken under general anesthesia. In awake patients, movements impede clinically useful OCT acquisition. Therefore, an automatic compensation of movements was implemented into a swept source OCT-laryngoscope. Video and OCT beam path were combined in one tube of 10-mm diameter. Segmented OCT images served as distance sensor and a feedback control adjusted the working distance between 33 and 70 mm by synchronously translating the reference mirror and focusing lens. With this motion compensation, the tissue was properly visible in up to 88% of the acquisition time. During quiet respiration, OCT contrasted epithelium and lamina propria. Mean epithelial thickness was measured to be 109 and [Formula: see text] in female and male, respectively. Furthermore, OCT of mucosal wave movements during phonation enabled estimation of the oscillation frequency and amplitude. Regarding clinical issues, the OCT-laryngoscope with automated working distance adjustment may support the estimation of the depth extent of epithelial lesions and contribute to establish an indication for a biopsy. Moreover, OCT of the vibrating vocal folds provides functional information, possibly giving further insight into mucosal behavior during the vibratory cycle.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481024PMC
http://dx.doi.org/10.1117/1.JMI.2.2.026003DOI Listing

Publication Analysis

Top Keywords

working distance
12
automated working
8
distance adjustment
8
optical coherence
8
coherence tomography
8
awake patients
8
oct
7
distance
4
adjustment enables
4
enables optical
4

Similar Publications

Free-Space to SMF Integration and Green to C-Band Conversion Based on PPLN.

Sensors (Basel)

December 2024

Graduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.

In this study, we experimentally demonstrate a PPLN-based free-space to SMF (single-mode fiber) conversion system capable of efficient long-wavelength down-conversion from 518 nm, optimized for minimal loss in highly turbid water, to 1540 nm, which is ideal for low-loss transmission in standard SMF. Leveraging the nonlinear optical properties of periodically poled lithium niobate (PPLN), we achieve a wavelength conversion efficiency of 1.6% through difference frequency generation while maintaining a received optical signal-to-noise ratio of 10.

View Article and Find Full Text PDF

Cross-Field Road Markings Detection Based on Inverse Perspective Mapping.

Sensors (Basel)

December 2024

Department of Geomatics, National Cheng Kung University, No. 1, University Rd., Tainan 701, Taiwan.

With the rapid development of the autonomous vehicles industry, there has been a dramatic proliferation of research concerned with related works, where road markings detection is an important issue. When there is no public open data in a field, we must collect road markings data and label them by ourselves manually, which is huge labor work and takes lots of time. Moreover, object detection often encounters the problem of small object detection.

View Article and Find Full Text PDF

In orchard environments, negative obstacles such as ditches and potholes pose significant safety risks to robots working within them. This paper proposes a negative obstacle detection method based on LiDAR tilt mounting. With the LiDAR tilted at 40°, the blind spot is reduced from 3 m to 0.

View Article and Find Full Text PDF

Wearable System Applications in Performance Analysis of RaceRunning Athletes with Disabilities.

Sensors (Basel)

December 2024

School of Sport and Physical Activity, College of Health, Wellbeing and Life Sciences, Sheffield Hallam University, Sheffield S10 2BP, UK.

RaceRunning is a sport for disabled people and successful performance depends on reducing the amount of time spent travelling a specific distance. Performance analysis in RaceRunning athletes is based on traditional methods such as recording race time, distances travelled and frequency (sets and reps) that are not sufficient for monitoring training loads. The aims of this study were to monitor training loads in typical training sessions and evaluate technical adaptations in RaceRunning performance by acquiring sensor metrics.

View Article and Find Full Text PDF

Unlabelled: Intake of New Zealand blackcurrant (NZBC) extract for 7 days has been shown to improve high-intensity intermittent running (HIIR) performance.

Objectives: We examined the repeat response of NZBC extract on HIIR performance.

Methods: Sixteen active males (age: 23 ± 3 yrs, height: 179 ± 5 cm, mass: 79 ± 11 kg, V˙O: 55.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!