Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841).
Methods: Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 ± 13 years (mean ± SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%.
Results: Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 ± 2.3 mm, and the average ring diameter used was 21.5 ± 1.6 mm. The preoperative AI grade (0-4) was 2.9 ± 0.8 and improved after repair to 0.6 ± 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 ± 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed.
Conclusions: Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.