A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fixation pattern of conical and cylindrical modular revision hip stems in different size bone defects. | LitMetric

Fixation pattern of conical and cylindrical modular revision hip stems in different size bone defects.

Int Orthop

Laboratory of Biomechanics and Implant Research, Department of Orthopaedics, Traumatology and Paraplegiology, University Hospital Heidelberg, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.

Published: September 2015

Purpose: Femoral defects often make it difficult to achieve sufficient fixation of the stem during revision surgery. No clinical studies comparing modular stems are available and differentiated recommendations are rare. The aim of this study was to compare the fixation of different revision stems in an experimental and standardised manner.

Methods: Segmental AAOS type I and III defects were reproduced in four femur pairs and two modular stems of different shape (cylindrical and conical) were implanted. Interfacial stem-bone movements were measured under axial torque application to analyze the stem fixation depending on defect extension.

Results: Both stems showed adequate fixation in AAOS type I defect. The defect extension significantly reduced the fixation of both implants. The fixation pattern changed significantly for the cylindrical-shaped stem but was maintained for the conical-shaped stem.

Conclusions: Shape as well as the extension of femoral defect have an impact on primary fixation. A type I defect seems to be bridgeable for both stems albeit in a different way. In contrast, stem-demanding activities during the healing phase have to be avoided for the conical-shaped stem in a type III defect, whereas the cylindrical-shaped stem has already ceased to be sufficiently stable in this case.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-015-2869-5DOI Listing

Publication Analysis

Top Keywords

fixation
8
fixation pattern
8
modular stems
8
aaos type
8
type iii
8
type defect
8
cylindrical-shaped stem
8
stems
6
defect
6
stem
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!