Background: In recent years there has been an improvement of zirconia ceramic materials to replace posterior missing teeth. To date little in vitro studies has been carried out on the fracture resistance of zirconia veneered posterior fixed dental prostheses. This study investigated the fracture resistance and the failure mode of 3-unit zirconia-based posterior fixed dental prostheses fabricated with two CAD/CAM systems.

Material And Methods: Twenty posterior fixed dental prostheses were studied. Samples were randomly divided into two groups (n=10 each) according to the zirconia ceramic analyzed: Lava and Procera. Specimens were loaded until fracture under static load. Data were analyzed using Wilcoxon´s rank sum test and Wilcoxon´s signed-rank test (P<0.05).

Results: Partial fracture of the veneering porcelain occurred in 100% of the samples. Within each group, significant differences were shown between the veneering and the framework fracture resistance (P=0.002). The failure occurred in the connector cervical area in 80% of the cases.

Conclusions: All fracture load values of the zirconia frameworks could be considered clinically acceptable. The connector area is the weak point of the restorations. Key words:Fixed dental prostheses, zirconium-dioxide, zirconia, fracture resistance, failure mode.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483332PMC
http://dx.doi.org/10.4317/jced.52067DOI Listing

Publication Analysis

Top Keywords

posterior fixed
16
fixed dental
16
dental prostheses
16
fracture resistance
12
resistance failure
8
failure mode
8
prostheses fabricated
8
zirconia ceramic
8
posterior
5
fracture
4

Similar Publications

Objective: Posterior cervical spine surgery can result in significant discomfort in the post-operative period. Post-operative pain management presents a challenge, particularly in the elderly population which is more sensitive to adverse effects from analgesia. We aimed to compare outcomes after peri-operative posterior cervical muscle plane blocks versus patients who received general anesthesia only.

View Article and Find Full Text PDF

Background: The occipital artery (OA) is an important donor artery for intracranial and extracranial bypass surgery, but its path is tortuous, making it difficult to harvest. Part of the traditional intermuscular OA is not covered by muscle and is easily damaged during surgery. Currently, there are few reports on how to protect this segment of the OA.

View Article and Find Full Text PDF

Background And Objectives: The middle fossa approaches are tremendously versatile for treating small vestibular schwannomas, selected petroclival meningiomas, midbasilar trunk aneurysms, and lesions of the petrous bone. Our aim was to localize the internal acoustic canal and safely drill the petrous apex with these approaches. This study demonstrates a new method to locate the internal acoustic canal during surgery in the middle fossa.

View Article and Find Full Text PDF

Microbothriid (Monogenean) Infection and Treatment in Captive Blacktip Reef Shark ().

Microorganisms

December 2024

Laboratory of Aquatic Biomedicine, Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Republic of Korea.

Unlike other microbothriid monogenean infections in elasmobranchs, limited information is available on the biology and treatment of . As parasitic infection with was found in 21 juvenile blacktip reef sharks () at the Lotteworld aquarium in Seoul, South Korea, we aimed to investigate the anatomical features and treatment protocols for in this study. The parasites were sampled and fixed in 10% neutral-buffered formalin, and examined using light and scanning electron microscopy.

View Article and Find Full Text PDF

Scan accuracy of recently introduced wireless intraoral scanners in different fixed partial denture situations.

J Dent

January 2025

Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland;; Department of Prosthetic Dentistry and Material Science, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.

Article Synopsis
  • The study aimed to compare the accuracy of new wireless intraoral scanners (IOSs) with traditional wired IOSs in different scenarios related to fixed partial dentures (FPDs).
  • Models of partially edentulous maxillae were scanned using both types of scanners and results were analyzed against reference scans to measure trueness and precision.
  • Findings revealed that while the wireless IOSs showed good accuracy, wired IOSs outperformed in certain metrics, particularly in angular and interimplant distance measurements, with higher inaccuracies noted in posterior FPDs.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!