Purpose: this study was conducted to investigate the influence of the popliteus tendon (PT) on the static stability of total knee arthroplasty (TKA).

Methods: twenty knees were used. In 10 right knees, a cruciate-retaining (CR) TKA trial prosthesis was implanted; in the other ten knees (left knees), the posterior cruciate ligament was cut and a posterior substitution (PS) TKA trial prosthesis was implanted. Lamina spreaders were set at 100 N of tension, one on the medial and one on the lateral articular space. Gaps were then measured with a caliper before and after PT sectioning.

Results: the correlation between femoral dimensions and popliteus insertion distance from articular surfaces was measured with the Pearson correlation index and considered significant. In the CR-TKA group, medial and lateral gap measurements showed a significant increase after PT sectioning both in flexion and in extension. In the PS-TKA group, lateral gap measurements showed a significant increase after PT sectioning both in flexion and in extension, while the medial gap measurements increased significantly only in flexion.

Conclusions: PT sectioning destabilized both the lateral and the medial aspects of the knee. A greater effect was observed in the lateral compartment. The most statistically reliable effect was observed with the knee in flexion. In addition, we observed that preserving the PCL does not prevent lateral gap opening after PT sectioning.

Clinical Relevance: PT should always be preserved when performing a TKA, because its resection can affect gap balancing, in flexion and in extension.

Type Of Study: controlled laboratory study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4469038PMC

Publication Analysis

Top Keywords

lateral gap
12
gap measurements
12
popliteus tendon
8
total knee
8
knee arthroplasty
8
tka trial
8
trial prosthesis
8
prosthesis implanted
8
medial lateral
8
measurements increase
8

Similar Publications

Purpose: This study reports the relationship between posterior cruciate ligament (PCL) retention vs resection and soft tissue laxity and balance throughout flexion using a robotically controlled ligament tensioner.

Methods: 55 robotic-assisted TKAs (Total knee arthroplasty) were retrospectively reviewe. The robotic ligament tensioner collected laxity data both before and after PCL resection.

View Article and Find Full Text PDF

Today, most research evaluation frameworks are designed to assess mature projects with well-defined data and clearly articulated outcomes. Yet, few, if any, are equipped to evaluate the promise of early-stage research, which is inherently characterized by limited evidence, high uncertainty, and evolving objectives. These early-stage projects require nuanced assessments that can adapt to incomplete information, project maturity, and shifting research questions.

View Article and Find Full Text PDF

Defining the Polycystin Pharmacophore Through HTS & Computational Biophysics.

bioRxiv

January 2025

Department of Pharmacology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.

Background And Purpose: Polycystins (PKD2, PKD2L1) are voltage-gated and Ca-modulated members of the transient receptor potential (TRP) family of ion channels. Loss of PKD2L1 expression results in seizure-susceptibility and autism-like features in mice, whereas variants in PKD2 cause autosomal dominant polycystic kidney disease. Despite decades of evidence clearly linking their dysfunction to human disease and demonstrating their physiological importance in the brain and kidneys, the polycystin pharmacophore remains undefined.

View Article and Find Full Text PDF

Introduction: As a hallmark feature of amyotrophic lateral sclerosis (ALS), bulbar involvement significantly impacts psychosocial, emotional, and physical health. A validated objective marker is however lacking to characterize and phenotype bulbar involvement, positing a major barrier to early detection, progress monitoring, and tailored care. This study aimed to bridge this gap by constructing a multiplex functional mandibular muscle network to provide a novel objective measurement tool of bulbar involvement.

View Article and Find Full Text PDF

Mechanoluminescent (ML) materials emit light by trapping and releasing charge carriers under mechanical stress. However, previous studies do not fully reveal the relationship between emitting light intensity and mechanical stress, thereby affecting the accuracy of stress measurement. This study addresses this gap by systematically investigating ML cylinders with various sizes and loading paths using theoretical analysis and simulations, focusing on the maximum contact stress, equivalent stress distribution, and the relationship between the strain energy density and light intensity at the point of maximum contact stress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!