A 72-year-old male patient with a 7-year history of cardioverter-defibrillator (ICD) implantation was admitted to our clinic with pocket infection. One year prior to this admission, he had undergone an unsuccessful extraction procedure at another clinic, during which the older broken ICD lead had been left in place and a newer ICD lead implanted via the same pocket. The newer and older leads were extracted by mechanical dilator sheath and needle eye snare respectively.

Download full-text PDF

Source
http://dx.doi.org/10.5543/tkda.2015.46080DOI Listing

Publication Analysis

Top Keywords

icd lead
8
challenging case
4
case transvenous
4
transvenous lead
4
lead extraction
4
extraction 72-year-old
4
72-year-old male
4
male patient
4
patient 7-year
4
7-year history
4

Similar Publications

Discovery of a Chimeric Polyketide Family as Cancer Immunogenic Chemotherapeutic Leads.

J Am Chem Soc

December 2024

Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina 29208, United States.

Discovery of cancer immunogenic chemotherapeutics represents an emerging, highly promising direction for cancer treatment that uses a chemical drug to achieve the efficacy of both chemotherapy and immunotherapy. Herein, we report a high-throughput screening platform and the subsequent discovery of a new class of cancer immunogenic chemotherapeutic leads. Our platform integrates informatics-based activity metabolomics for the rapid identification of microbial natural products with both novel structures and potent activities.

View Article and Find Full Text PDF

Objective: Identification of therapeutic targets in the treatment of adolescent depression with attenuated symptoms of schizophrenia and assessment of the effectiveness of therapeutic interventions.

Material And Methods: One hundred and twenty-three patients (mean age 19.6±2.

View Article and Find Full Text PDF

Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.

Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.

View Article and Find Full Text PDF

Enhancing Ferroptosis-Mediated Radiosensitization Synergistic Disulfidptosis Induction.

ACS Nano

December 2024

Guangzhou Key Laboratory of Tumor Immunology Research, Cancer Research Institute, School of Basic Medical Sciences, Southern Medical University, Guangzhou 510515, P.R. China.

Ferroptosis plays an important role in radiotherapy (RT), and the induction of ferroptosis can effectively sensitize radiotherapy. However, the therapeutic efficiency is always affected by ferroptosis resistance, especially SLC7A11 (Solute Carrier Family 7 Member 11)-cystine-cysteine-GSH (glutathione)-GPX4 (glutathione peroxidase 4) pathway-mediated resistance. In this study, tumor-microenvironment self-activated high-Z element-containing nanoferroptosis inducers, PEGylated Fe-Bi-SS metal-organic frameworks (FBSP MOFs), were developed to sensitize RT.

View Article and Find Full Text PDF

Stubborn biofilm infections pose serious threats to public health. Clinical practices highly rely on mechanical debridement and antibiotics, which often fail and lead to persistent and recurrent infections. The main culprits are 1) persistent bacteria reviving, colonizing, and rejuvenating biofilms, and 2) secondary pathogen exposure, particularly in individuals with chronic diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!