Our objective is to describe the use of a ventricular assist device (VAD) in single-ventricle patients with circulatory failure following superior cavopulmonary anastomosis (SCPA). We performed a retrospective chart review of all single-ventricle patients supported with a VAD following SCPA. Implantation techniques, physiologic parameters while supported, medical and surgical interventions postimplant, and outcomes were reviewed. Four patients were supported with an EXCOR Pediatric (Berlin Heart Inc., The Woodlands, TX, USA) following SCPA for a median duration of 10.5 days (range 9-312 days). Selective excision of trabeculae and chords facilitated apical cannulation in all patients without inflow obstruction. There were two pump exchanges in the one patient supported for 312 days. Two patients were evaluated by cardiac catheterization while supported. Three of four patients were successfully bridged to transplantation. One patient died while supported. All patients had significant bleeding at the time of transplantation, and one required posttransplant extracorporeal membrane oxygenation with subsequent full recovery. VAD support can provide a successful bridge to transplantation in patients with single-ventricle circulation following SCPA. A thorough understanding of the challenges encountered during this support is necessary for successful outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.12531DOI Listing

Publication Analysis

Top Keywords

ventricular assist
8
assist device
8
superior cavopulmonary
8
cavopulmonary anastomosis
8
patients
8
single-ventricle patients
8
patients supported
8
supported
6
single-ventricle
4
device single-ventricle
4

Similar Publications

Primary graft dysfunction (PGD) is the most common cause of early mortality following heart transplantation. Although PGD can affect both ventricles, isolated right ventricular dysfunction (RV-PGD) is observed in nearly half of PGD patients. RV-PGD requires specific medical management to support the preload, afterload, and function of the failing RV; however, the use of mechanical circulatory support of the RV (RV-MCS) might be required when optimal medical therapy is insufficient in preventing forward failure and retrograde venous congestion.

View Article and Find Full Text PDF

Prompt emergence from general anesthesia is crucial after neurosurgical procedures, such as craniotomies, to facilitate timely neurological evaluation for identification of intraoperative complications. Delayed emergence can be caused by residual anesthetics, metabolic imbalances, and intracranial pathology, for which an eye examination can provide early diagnostic clues. The sunset sign (or setting sun sign), characterized by a downward deviation of the eyes, can be an early indicator of raised intracranial pressure (ICP) or midbrain compression, as is commonly observed in states of hydrocephalus or periaqueductal or tectal plate dysfunction.

View Article and Find Full Text PDF

Background: Acute type A aortic dissection (A-AAD) with severe acute aortic regurgitation (AR) and coronary involvement is a potentially fatal condition that causes left ventricular volume overload and catastrophic acute myocardial infarction. We present the successful management of a patient using Impella 5.5 following cardiopulmonary arrest caused by A-AAD with severe acute AR and left main trunk (LMT) obstruction.

View Article and Find Full Text PDF

Background: To evaluate the feasibility, effectiveness and assistant effect of 3D printed aortic model in the treatment on congenital coarctation of the aorta (CoA) in adolescents and adults.

Methods: From December 2018 to December 2023, a total of 10 patients with congenital coarctation of aorta underwent percutaneous balloon dilatation covered stent implantation in the department of cardiovascular surgery, Xijing Hospital. There were 6 males and 4 females whose average age was (27.

View Article and Find Full Text PDF

Objective: The objective was to evaluate the etiology, natural history, and impact of surgical intervention on outcomes of left ventricular assist device (LVAD) patients presenting with intracranial hemorrhage (ICH).

Methods: The authors completed a retrospective review of LVAD patients who presented with ICH at 2 centers between 2013 and 2022. Patients were reviewed for demographic, clinical, and radiographic variables.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!