Dental Implant Supported Restorations Improve Quality of Life in Osteoporotic Women.

Int J Dent

Department of Periodontics, School of Dental Medicine, Case Western Reserve University, 2124 Abington Road, Cleveland, OH 44106, USA.

Published: July 2015

Introduction. The aim of this study is to compare the quality of life (QoL) in partially edentulous osteoporotic women who have missing teeth restored with dental implant retained restorations with those who do not and, secondarily, to report the rate of osteonecrosis in this sample. Methods. 237 participants completed the Utian QoL survey, a 23-question document measuring across psychosocial domains of well-being including occupational, health, emotional, and sexual domains which together contribute to an overall score. The subset of participants having dental implant supported prosthesis (64) was compared to the subset having nonimplant supported fixed restorations (47), the subset having nonimplant supported removable restorations (60), and the subset having no restoration of missing teeth (66). Results. ANOVA showed significant difference in all QoL domains between the four subsets (p < 0.05). Although 134 reported oral bisphosphonate and 51 reported IV bisphosphonate use, no signs of ONJ were identified in any participants. Conclusion. These findings show implant retained oral rehabilitation has a statistically significant impact over nonimplant and traditional fixed restorations, removable restorations, and no restoration of missing teeth in far reaching areas including occupational, health, emotional, sexual, and overall QoL. These findings also support future examination of psychosocial outcomes associated with oral rehabilitation and the incorporation of oral health into women's health promotion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4469828PMC
http://dx.doi.org/10.1155/2015/451923DOI Listing

Publication Analysis

Top Keywords

dental implant
12
missing teeth
12
implant supported
8
quality life
8
osteoporotic women
8
implant retained
8
including occupational
8
occupational health
8
health emotional
8
emotional sexual
8

Similar Publications

Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.

Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).

Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.

View Article and Find Full Text PDF

The submandibular displacement of a mandibular third molar residual root presents major challenges to oral and maxillofacial surgeons due to the proximity to critical anatomical structures such as the lingual nerve and sublingual artery. Preoperative imaging can approximate the location of the residual tooth root; however, accurately determining its exact position is difficult because of the dynamic nature of the mandible and the difficulty of real-time synchronization of imaging. This study presents the successful extraction of a residual mandibular third molar root in a 67-year-old female patient achieved using a magnetic field-based navigation system.

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate the long-term clinical outcomes of one-piece narrow-diameter implants (NDIs), with diameters of 2.5 mm and 3.0 mm, and to investigate the factors that affect marginal bone loss (MBL) around these implants.

View Article and Find Full Text PDF

Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.

Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!