A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long Term Outcomes Following Freestyle Stentless Aortic Bioprosthesis Implantation: An Australian Experience. | LitMetric

Long Term Outcomes Following Freestyle Stentless Aortic Bioprosthesis Implantation: An Australian Experience.

Heart Lung Circ

Sydney Medical School, University of Sydney, Sydney, NSW, Australia; The Baird Institute for Applied Heart and Lung Surgical Research, Sydney, NSW, Australia; Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Sydney, NSW, Australia; Australian School of Advanced Medicine, Macquarie University, Sydney, NSW, Australia. Electronic address:

Published: January 2016

Background: The Freestyle stentless bioprosthesis (FSB) has been demonstrated to be a durable prosthesis in the aortic position. We present data following Freestyle implantation for up to 10 years post-operatively and compare this with previously published results.

Methods: A retrospective cohort analysis of 237 patients following FSB implantation occurred at five Australian hospitals. Follow-up data included clinical and echocardiographic outcomes.

Results: The cohort was 81.4% male with age 63.2±13.0 years and was followed for a mean of 2.4±2.3 years (range 0-10.9 years, total 569 patient-years). The FSB was implanted as a full aortic root replacement in 87.8% patients. The 30-day all cause mortality was 4.2% (2.0% for elective surgery). Cumulative survival at one, five and 10 years was 91.7±1.9%, 82.8±3.8% and 56.5±10.5%, respectively. Freedom from re-intervention at one, five and 10 years was 99.5±0.5%, 91.6±3.7% and 72.3±10.5%, respectively. At latest echocardiographic review (mean 2.3±2.1 years post-operatively), 92.6% had trivial or no aortic regurgitation. Predictors of post-operative mortality included active endocarditis, acute aortic dissection and peripheral vascular disease.

Conclusions: We report acceptable short and long term outcomes following FSB implantation in a cohort of comparatively younger patients with thoracic aortic disease. The durability of this bioprosthesis in the younger population remains to be confirmed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hlc.2015.05.011DOI Listing

Publication Analysis

Top Keywords

long term
8
term outcomes
8
freestyle stentless
8
years post-operatively
8
fsb implantation
8
years
7
aortic
6
outcomes freestyle
4
stentless aortic
4
aortic bioprosthesis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!