Background: Trochanteric fractures are common but difficult to analyse in the elderly on plain X-rays. Fixation failures are related to the severity of the comminution, but comminution and the degree of instability are not easy to determine on standard X-rays. Use of computed tomography (CT) improves assessment of complex fractures, but this finding has not been confirmed versus intraoperative data. The primary objective of this prospective study was to determine the error rate when evaluating comminution on X-rays and CT scans. The secondary objectives were to determine whether CT data on comminution and stability were consistent with intraoperative findings and to define the fracture characteristics.

Hypothesis: Standard X-ray assessment underestimates the complexity of trochanteric fractures and is not very reproducible.

Methods: Between January and December 2013, all proximal femur fractures in the trochanter area of patients aged 75 years or older (mean age 85) were analysed prospectively with standard X-rays and computed tomography (CT). One hundred and ten patients (88 women and 22 men) with trochanteric fractures were included in the study. Fracture stability was evaluated using the Müller AO classification; the other fracture characteristics were evaluated independently. A senior surgeon evaluated the anonymised X-rays. A radiologist specialised in musculoskeletal imaging interpreted the CT scan images. All patients underwent total hip arthroplasty (110 patients) and 104 fixations of the greater trochanter. The X-ray and CT findings were compared to the intraoperative findings (gold standard) to evaluate their reproducibility.

Results: The reproducibility of the X-ray evaluation was poor for comminution, with a kappa of 0.4, sensitivity of 44 % and a negative predictive value of 29 % but a positive predictive value and specificity of 100 %. The CT evaluation had a kappa of 0.94, sensitivity of 95 % and negative predictive value of 79 %. According to the AO classification, unstable fractures were found in 65 patients based on X-rays, 80 patients based on CT scan and 83 patients based on intraoperative findings. Comminution was mainly identified during surgery; it was medial in 34 % of cases, posterior in 22 % and posteromedial in 21.8 %.

Discussion And Conclusion: In the current study, 75.4 % of fractures were complex and unstable, with medial and/or posterior comminution present in three-quarters of these fractures. X-ray assessment underestimates posterior comminution and the complexity of the fracture line and was not very reproducible. The current results of this study suggest that comminution contributes to instability and that this finding is not taken into account in the AO classification, which is not well suited for this type of fracture and raises the question of how to best evaluate and treat these fractures.

Level Of Evidence: Prospective diagnostic study, Level III.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-015-1666-6DOI Listing

Publication Analysis

Top Keywords

trochanteric fractures
12
intraoperative findings
12
patients based
12
comminution
10
prospective study
8
x-rays scans
8
fractures
8
standard x-rays
8
x-rays computed
8
computed tomography
8

Similar Publications

Unlabelled: Using the UK Clinical Practice Research Datalink, our cohort study matched 237,297 individuals with hearing loss (HL) to 829,431 without HL. The study found an 8-10% higher risk of major osteoporotic fracture in individuals with HL compared to those without. Additionally, within the HL cohort, we identified risk factors for potential inclusion in fracture risk models.

View Article and Find Full Text PDF

Characterization of LIPUS Parameters Suitable for Hip Bone Fracture.

Ultrasound Med Biol

January 2025

Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; Research Institute of Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China. Electronic address:

Objective: To investigate the effects of ultrasound treatment on the healing of hip bone fractures using frequencies of 0.5 MHz and 1.5 MHz with constant intensity (30 mW/cm) at the fractured site.

View Article and Find Full Text PDF

Hip fractures (HFs) are common in elderly patients and are associated with high mortality rates and functional impairment. Malnutrition has been shown to negatively impact postoperative survival rates in HF patients. However, the relationship between the Geriatric Nutrition Risk Index (GNRI) and the risk of HF remains unclear.

View Article and Find Full Text PDF

To investigate the clinical efficacy of using different approach sciatic nerve blocks on the sciatic nerve depth and pain degree in patients with ankle fracture. A retrospective analysis was conducted on 151 patients with ankle fractures who were admitted to the hospital from May 2020 to May 2023. The patients were divided into a control group (n=76) using the greater trochanteric plane approach (GTA) and an observation group (n=75) using the suprapopliteal approach (PA).

View Article and Find Full Text PDF

: This study aimed to investigate the differences in spatiotemporal gait parameters in patients who underwent surgery for hip fractures when using walking poles and T-canes. : This cross-sectional study enrolled eight patients who underwent surgery for a unilateral hip fracture (mean age of 79.0 ± 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!