A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems. | LitMetric

Purpose: To compare the reliability and stability of the multicomponent-driven equilibrium single pulse observation of T1 and T2 (mcDESPOT) and Carl-Purcell-Meiboom-Gill (CPMG) approaches to parameter estimation.

Methods: The stability and reliability of mcDESPOT and CPMG-derived parameter estimates were compared through examination of energy surfaces, evaluation of model sloppiness, and Monte Carlo simulations. Comparisons were performed on an equal time basis and assuming a two-component system. Parameter estimation bias, reflecting accuracy, and dispersion, reflecting precision, were derived for a range of signal-to-noise ratios (SNRs) and relaxation parameters.

Results: The energy surfaces for parameters incorporated into the mcDESPOT signal model exhibit flatness, a complex structure of local minima, and instability to noise to a much greater extent than the corresponding surfaces for CPMG. Although both mcDESPOT and CPMG performed well at high SNR, the CPMG approach yielded parameter estimates of considerably greater accuracy and precision at lower SNR.

Conclusion: mcDESPOT and CPMG both permit high-quality parameter estimates under SNR that are clinically achievable under many circumstances, depending upon available hardware and resolution and acquisition time constraints. At moderate to high SNR, the mcDESPOT approach incorporating two-step phase increments can yield accurate parameter estimates while providing values for longitudinal relaxation times that are not available through CPMG. However, at low SNR, the CPMG approach is more stable and provides superior parameter estimates. Magn Reson Med 75:2406-2420, 2016. © 2015 Wiley Periodicals, Inc.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5958911PMC
http://dx.doi.org/10.1002/mrm.25801DOI Listing

Publication Analysis

Top Keywords

parameter estimates
24
parameter
8
cpmg-derived parameter
8
energy surfaces
8
mcdespot cpmg
8
high snr
8
snr cpmg
8
cpmg approach
8
cpmg
7
estimates
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!