Purpose: To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D) space.
Methods: Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium). The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly.
Results: The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r = 0.24, p < 0.01) and between the femoral length and the isthmus height (r = 0.6, p < 0.01). Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus.
Conclusion: The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4475546 | PMC |
http://dx.doi.org/10.1155/2015/459612 | DOI Listing |
J Robot Surg
January 2025
The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.
The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Twin Cities Orthopedics, Edina, Minnesota, USA.
Background: Anterior cruciate ligament (ACL) stress techniques-including single-leg stress radiographs, Telos, and KT-1000 arthrometer-are highly accessible and can provide additional diagnostic information to assess ACL and ACL graft integrity. The degree of anterior tibial translation (ATT) may be useful in guiding treatment when a diagnosis on magnetic resonance imaging is not conclusive or for judging if additional treatments, such as anterolateral complex augmentation, may be necessary.
Purpose/hypothesis: The purpose of this study was to evaluate the effect of increasing posterior tibial slope (PTS) on baseline tibial position (BTP) and side-to-side differences (SSD) in ATT.
Front Surg
December 2024
Department of Orthopedics, Jinjiang Municipal Hospital/Clinical Research Center for Orthopaedic Trauma and Reconstruction of Fujian Province, Jinjiang, Quanzhou, Fujian, China.
Objective: By comparing the hip arthroplasty parameters planned with the AIHIP three-dimensional simulation surgery system, this study analyzes the accuracy of the new femoral-side "shoulder-to-shoulder" artificial anatomical marker positioning method in femoral-side prosthesis implantation and the prevention of leg length discrepancy in hip arthroplasty.
Methods: A retrospective collection of 47 patients who underwent initial total hip arthroplasty at our hospital from August 2020 to December 2022 and met the inclusion and exclusion criteria was used as the study subjects. The average age was 67.
Clin Orthop Relat Res
December 2024
Department of Orthopedics, University of Colorado School of Medicine, Aurora, CO, USA.
World J Orthop
December 2024
Department for Science, Dubai College, Dubai 00000, Dubayy, United Arab Emirates.
Hip arthroplasty in patients with a history of paediatric hip disorders presents a significant challenge for orthopaedic surgeons. These patients are typically younger and have greater functional demands. Therefore, achieving optimal biomechanical conditions is crucial, involving placement of the acetabulum at the ideal centre of rotation and securing a stable femoral component with good offset to preserve abductor muscle function and restore leg length.